Use the lsportfc command to view the status and properties of the Fibre Channel (FC) input/output (I/O) ports for the clustered system.
This command enables you to view information about clustered system port status.
lsportfc output provides the attribute values that can be displayed as output view data.Attribute | Description |
---|---|
id | Indicates a unique value for the object. The value must be a numeric 0 or greater. |
fc_io_port_id | Indicates the FC I/O port ID. The value must be a positive integer. |
port_id | Indicates the platform port ID. The value must be a positive integer. |
type | Indicates the type of platform port. The value can be either fc or ethernet. |
port_speed | Indicates the I/O port speed. The value is XGb. The value is N/A if the port has never been active. If the port is inactive, it shows the last-known port speed. |
node_id | Indicates the ID of the node containing the port. The value must be a positive integer. |
node_name | Indicates the name of the node containing the port. |
WWPN | Indicates the I/O port worldwide port name (WWPN). The value must be in 16-character hexadecimal format. |
nportid | Indicates the most recent NPort ID used by the port. The value must be in 6-character hexadecimal format, and all zeroes if never active. |
status | Indicates whether the port is configured to a device of Fibre Channel (FC)
port. The values are:
|
switch_WWPN | Indicates the WWPN of the device that was most recently attached to the port. The value must be in 16-character hexadecimal format, or all zeroes if the port has never been active. |
vlan_id | Indicates the VLAN ID on which a specific VN port is communicating. The value is up to a 4-character decimal string. The value is N/A for ports that are never active. If the port is inactive, the last-known VLAN ID is used. |
fcf_MAC | Indicates the MAC address for the switch attached to the VN port. The value is N/A for ports that are never active. The value is a formatted 48-bit MAC address. If the port is inactive, the last known fcf_MAC value is used. |
attachment | Indicates if the port is attached to an FC switch or directly to an FC host. (Or, if the port is offline, it specifies which one it was attached to when last online.) |
cluster_use | Indicates the node's current capability for local or partner cluster
communications:
|
adapter_location | Indicates the location of the adapter containing the Ethernet port (any number from 0 to 6). |
adapter_port_id | Indicates the location of the Ethernet port that is in the adapter (any number from 1 to 4). |
fabric_WWN | Indicates the World Wide Name (WWN) value for the connected fabric string. The value must be in 16-character hexadecimal format, or all zeroes if the port has never been active or the port is not connected to a fabric. |
lsportfc
The resulting output:
id fc_io_port_id port_id type port_speed node_id node_name WWPN nportid status attachment cluster_use adapter_location adapter_port_id 0 1 1 fc 8Gb 1 node1 500507680140BADD 0E2411 active switch local_partner 1 1 1 2 2 fc 8Gb 1 node1 500507680130BADD 0E2412 active switch local_partner 1 2 2 3 3 fc N/A 1 node1 500507680110BADD 000000 inactive_unconfigured none partner 1 3 3 4 4 fc N/A 1 node1 500507680120BADD 000000 inactive_unconfigured none none 1 4 4 5 3 ethernet 10Gb 1 node1 500507680150BADD 0E2413 active switch local 2 1 5 6 4 ethernet 10Gb 1 node1 500507680160BADD 0E2414 inactive_configured switch local 2 2 6 1 1 fc N/A 2 node2 500507680140BADE 000000 inactive_unconfigured none local_partner 2 3 7 2 2 fc N/A 2 node2 500507680130BADE 000000 inactive_unconfigured none local_partner 2 4 8 3 3 fc N/A 2 node2 500507680110BADE 000000 inactive_unconfigured none partner 3 1 9 4 4 fc N/A 2 node2 500507680120BADE 0E2414 active switch none 3 2 10 5 3 ethernet 10Gb 2 node2 500507680150BADE 0E2415 active switch local 3 3 11 6 4 ethernet 10Gb 2 node2 500507680160BADE 0E2416 active switch local 3 4
lsportfc 10
The detailed resulting output:
id 10
fc_io_port_id 5
port_id 3
type ethernet
port_speed 10Gb
node_id 6
node_name node3
WWPN 50050768015051E5
nportid 012701
status active
switch_WWPN 202700053346FA3D
fpma 0E:FC:00:01:27:01
vlanid 100
fcf_MAC 00:05:73:C2:CA:B4
cluster_use none
adapter_location 1
adapter_port_id 1
fabric_WWN 202700053346FA3C