You can replace faulty support rails with new ones received
from CRU / FRU stock.
Two persons are required at step
7
To replace the support rails, complete the following
steps.
- Identify the enclosure mounted on the rails being replaced.
- Shut down the system by following
the steps in Procedure: Powering off your Lenovo Storage V7000 Gen2 system.
- Remove power from the enclosure by unplugging both power
cables from the electrical outlets.
- Ensuring you identify which port each cable connects to,
remove all cables from the back of the enclosure that has faulty support
rails.
- Remove the
end caps from the front flanges of the enclosure by following the
removal instructions in topic Replacing Lenovo Storage V7000 Gen2 enclosure end caps.
- Unscrew the M5 screw from the left flange.
Repeat with the M5 screw in the right flange.
- Slide the enclosure from the rack.
CAUTION:
The weight of this part or unit is between
18 and 32 kg (39.7 and 70.5 lb). It takes two persons to safely lift
this part or unit. (C009)
- Locate the left support rail.
Record the shelf number of the support rail so that the replacement
rails can be installed into the same position.
- At the rear of the rack, remove the
securing M5 screw from the bottom hole of the rear bracket of the
rail, then open the rear hinge bracket (Figure 1).
Figure 1. Opening rear hinge bracket of mounting rail
- At the front of the rack, hold onto the rail and open the
front hinge bracket.
- Compress the rail against its spring
to shorten it, then remove it from inside the rack (Figure 2).
Figure 2. Compressing rail for removal from rack
- Repeat steps 9 to Figure 2 on the right
support rail.
- Install the new support rails at the rack position that
is recorded at step 8 by
following the instructions in Installing support rails for Lenovo Storage V7000 expansion enclosures.
- Reinstall the enclosure (removed at
step 7) and the end caps (removed at step 5)
by following the instructions in Installing the enclosures.
- If components were removed from the enclosure at step 7,
return each canister, drive assembly, and power supply unit to its
labeled slot.
- Reconnect the cables, ensuring that they are connected
to their original ports.
- Reconnect the power supply cables to their original power
supply and electrical outlet.
- After the system is online, use the management GUI to verify that the system is correct.