Each expansion canister has two LEDs that provide status
and identification for the expansion canister.
The two LEDs are located in a vertical row on the left
side of the canister.
Figure 1 shows
the LEDs (
1) in the rear of the expansion canister.
Figure 1. LEDs on the expansion canisters
Table 1 describes the expansion canister
LEDs.
Table 1. Expansion canister LEDs
Name |
Description |
Color |
Symbol |
Status |
Indicates if the canister is active.
- If the LED is on, the canister is active.
- If the LED is off, the canister is not active.
- If the LED is flashing, there is a vital product data (VPD) error.
|
Green |
|
Fault |
Indicates if a fault is present and identifies
the canister.
- If the LED is on, a fault exists.
- If the LED is off, no fault exists.
- If the LED is flashing, the canister is being identified. This
status might or might not be a fault.
|
Amber |
|