Use the lscontroller command to display a concise list or a detailed view of controllers that are visible to the system.
This command returns a concise list, or a detailed view, of controllers visible to the system.
degraded no, yes
To differentiate the name of a storage controller from the name that is shown on the system, list the storage controllers by issuing the lscontroller command. Record the controller name or ID for the controller that you want to determine. For the controller in question, issue the lscontrollercontroller name | id command, where controller name | id is the controller name or ID. Record the worldwide node name (WWNN) for the controller. You can use the WWNN to determine the actual storage controller by launching the native controller user interface, or by using the command line tools that it provides to verify the actual controller that has the WWNN.
Attribute | Possible Values |
---|---|
id | Indicates the controller ID. |
name | Indicates the controller name. |
WWNN | Indicates the worldwide node name (WWNN). This field is blank for iSCSI controllers. |
mdisk_link_count | Indicates the MDisk link count. |
max_mdisk_link_count | Indicates the maximum MDisk link count. |
degraded | Indicates whether the controller has degraded MDisks. |
vendor_id | Indicates the vendor identification name or number. |
product_id_low | Indicates the product identification. |
product_id_high | Indicates the product identification. |
product_revision | Indicates the product revision. |
ctrl_s/n | Indicates the controller serial number. |
allow_quorum | Indicates that the controller can support quorum disks. |
WWPN | Indicates the worldwide port name (WWPN). This field is blank for iSCSI controllers. |
path_count | Indicates the number of paths that are currently being used to submit input/output (I/O) data to the controller port. |
max_path_count | Indicates the maximum number of paths that are currently being used to submit input/output (I/O) data to the controller port. |
site_id | Indicates the site value for the controller. This numeric value is 1, 2, 3, or blank. |
site_name | Indicates the site name for the controller. This value is an alphanumeric value or is blank. |
fabric_type | Indicates a Fibre Channel (FC) or SAS controller.
|
iscsi_port_id | Indicates the I/O port identifier, which is the same as the WWPN value
from the FC domain. This value shows the iSCSI port ID for the iSCSI controller and is
blank for other controllers. This value must be a numeric value. This ID refers to the row number in output from the lsiscsistorageport command. The lsiscsistorageport can be used to find the controller IQN. |
ip | Indicates the IP address that is associated with the iscsi_port_id. This value shows the IP value for the iSCSI controller and is blank for other controllers. This value must be an IPv4 or IPv6 address. |
physical_capacity | Indicates the physical capacity of the controller. This value is always blank or empty for controllers that do not report physical capacity information. |
lscontroller -delim :
The concise resulting output:
id:controller_name:ctrl_s/n:vendor_id:product_id_low:product_id_high:WWNN:degraded:fabric_type:site_id:site_name 0:controller0::IBM:1726-4xx:FAStT::no:iscsi:1:snpp1 1:controller1::IBM:1726-4xx:FAStT::no:iscsi:2:snpp2 7:controller7:3EK0J5Y8:SEAGATE :ST373405:FC:200600A0B851061E:yes:fc:1:snpp1 8:controller8:3EK0J6CR:SEAGATE :ST373405:FC:200600A0B851061D:no:fc:2:snpp2 9:controller9:3EK0J4YN:SEAGATE :ST373405:FC:200600A0B851061C:no:fc:3:snpp3 10:controller10:3EK0GKGH:SEAGATE :ST373405:FC:200600A0B851061B:no:fc:1:snpp4 11:controller11:3EK0J85C:SEAGATE :ST373405:FC:200600A0B851061A:no:fc:2:snpp5 12:controller12:3EK0JBR2:SEAGATE :ST373405:FC:200600A0B851062A:no:fc:3:snpp6 13:controller13:3EKYNJF8:SEAGATE :ST373405:FC:200600A0B851062B:no:fc:1:snpp7 14:controller14:3EK0HVTM:SEAGATE :ST373405:FC:200600A0B851062C:no:fc:2:snpp8
lscontroller -delim = 7
The detailed resulting output:
id=7 controller_name=controller7 WWNN=20000004CF2412AC mdisk_link_count=1 max_mdisk_link_count=1 degraded=no vendor_id=SEAGATE product_id_low=ST373405 product_id_high=FC product_revision=0003 ctrl_s/n=3EK0J5Y8 allow_quorum=no WWPN=22000004CF2412AC path_count=1 max_path_count=1 WWPN=21000004CF2412AC path_count=0 max_path_count=0 fabric_type=sas_direct iscsi_port_id= ip=physical_capacity=20.0GB
lscontroller 0
The detailed resulting output:
id 0
controller_name controller0
WWNN
mdisk_link_count 4
max_mdisk_link_count 4
degraded no
vendor_id IBM
product_id_low 1726-4xx
product_id_high FAStT
product_revision 0617
ctrl_s/n
allow_quorum no
fabric_type iscsi
site_id
site_name
WWPN
path_count 4
max_path_count 4
iscsi_port_id 1
ip 10.10.10.1
WWPN
path_count 4
max_path_count 4
iscsi_port_id 2
ip 10.10.10.2
physical_capacity 40.0GB