Use the rescuenode command to start automatic recovery for a specific
node.
Syntax
satask rescuenode -force [ panel_name ]
Parameters
- panel_name
- (Optional) Identifies the node that is being serviced.
Note: If panel_name
is not supplied, it applies to the node on which the command is
running.
- -force
- (Required) The -force parameter is required because this service
action can cause temporary or permanent loss of access to data. Use this command only when the
node reports corrupted system code.
Important: Using the force parameter might
result in a loss of access. Use it only under the direction of the IBM Support
Center.
Description
This command starts automatic recovery for a specific node. Use this command only when the
node reports corrupted code.
An invocation
example
satask rescuenode -force 112233
The resulting output:
No feedback