There are limitations in switch zoning between the system and the EMC Symmetrix and Symmetrix DMX systems.
The system switch zone must include at least one target port on two or more Fibre Channel adapters to avoid a single point of failure.
The EMC Symmetrix and Symmetrix DMX must be configured to present logical units (LUs) to all system initiator ports that are in the fabric zone.
Only system initiator ports that are LUN masked on the EMC Symmetrix or Symmetrix DMX controller can be present in the fabric zone.
You can connect a maximum of 16 EMC Symmetrix or Symmetrix DMX ports to the system. This maximum is the only special zoning requirement. Configurations that are set up to adhere to the requirements that are described in previous system releases are also supported. Do not follow previous requirements for new installations.