Metro Mirror and Global Mirror partnerships define an association between a local system and a partner system.
Before a Metro Mirror or Global Mirror relationship or consistency group can be created with a remote system, a partnership between the two systems must be established. If Global Mirror or Metro Mirror relationships or consistency groups exist between two remote systems, those systems must maintain their partnership. Each system can maintain up to three partnerships, and each partnership can be with a single partner system. As many as four systems can be directly associated with each other.
Systems also become indirectly associated with each other through partnerships. If two systems each have a partnership with a third system, those two systems are indirectly associated. A maximum of four systems can be directly or indirectly associated.
The nodes within the system must know not only about the relationship between the two volumes but also about an association among systems.
The following examples show possible Fibre Channel partnerships that can be established amongthe systems.
The following examples show Fibre Channel and IP partnerships that can be established withthe systems. For more information about configuring and deploying systems with IP partnerships, see Configuring IP partnerships.
To establish a Metro Mirror and Global Mirror partnership between two systems that are connected through Fibre Channel connections, you must run the mkfcpartnership command from both systems. For example, to establish a partnership between system A and system B, you must run the mkfcpartnership command from system A and specify system B as the remote system. The partnership is then partially configured and is sometimes described as one-way communication. Next, you must run the mkfcpartnership command from system B and specify system A as the remote system. When this command completes, the partnership is fully configured for two-way communication between the systems. If the local and remote system uses IP connections, you need to enter the mkippartnership command on both the local and remote system to fully configure the partnership. You can also use the management GUI to create Metro Mirror and Global Mirror partnerships.
In addition to Fibre Channel and Fibre Channel over Ethernet (FCoE) connections, Metro Mirror and Global Mirror partnerships can be established over Ethernet links using the IPv4 and IPv6 addresses associated with Ethernet ports. These IP partnerships can be connections through Ethernet switches, or direct connections between local and partner systems. Partnerships must be created as either an IPv4 or IPv6 partnership. Data compression is also supported for IPv4 or IPv6 partnerships. To enable data compression, both systems in an IP partnership must be running a software level that supports IP partnership compression. To fully enable compression in an IP partnership, each system must enable compression. When compression is enabled on the local system, data sent to the remote system is compressed. To send compressed data to the local system, the remote system in the IP partnership must also enable compression.
Remote-copy groups are unique to IP partnerships and contain local and remote IP addresses accessible to each other through an IP partnership. A remote-copy group must contain at least one IP address in the local system and one IP address in the remote system. You must create the remote-copy groups before establishing the IP partnership.
Each Ethernet port can be associated with two IP addresses; one using IPv4 addressing and the other using IPv6. Use either IPv4 or IPv6 for IP partnership. You should configure more than two IP addresses within one system of the remote-copy group to allow for IP connection failover if the local or partner system experiences a node or port failure.
To change Metro Mirror and Global Mirror partnerships, use the chpartnership command. To delete Metro Mirror and Global Mirror partnerships, use the rmpartnership command.
In a multiple-cycling Global Mirror copy, the linkbandwidthmbits parameter of the mkfcpartnership and mkippartnership commands controls the rate at which updates are propagated to the remote system. To ensure that the remote copies are as similar as possible to the local copies, the bandwidth parameter needs to be at least the average rate that write operations are applied to all volumes that are replicated by using multiple-cycling Global Mirror across this partnership. For optimum remedial process optimization (RPO), keep the bandwidth parameter less than the actual available bandwidth to ensure that multiple-cycling Global Mirror relationships do not congest the fabric. Also, leave sufficient bandwidth for Metro Mirror and noncycling Global Mirror relationships to support the I/O that are being replicated.
Before creating an IP partnership, define a CHAP secret for each system, then configure CHAP to be used for IP partnerships on each system.
For example, when creating an IP partnership that uses CHAP between system A and system B, first define a CHAP secret on each system. The CHAP secret value on systems A and B can differ. On system A, specify the system B CHAP secret in the Create Partnership or Partnership Properties dialog, then on system B, specify the system A CHAP secret using one of the dialogs.
When creating an IP partnership on a local system using CHAP, if you do not specify the system-wide CHAP secret of the partner system, the local system displays a CHAP authentication failure message. If an IP partnership using CHAP is active, you must stop the partnership before modifying the CHAP configuration.
You can create partnerships with SAN Volume Controller and other Lenovo V series family systems to allow Metro Mirror and Global Mirror to operate between the two systems. To create these partnerships, the clustered systems must be at version 6.3.0 or later.
A clustered system is in one of two layers: the replication layer or the storage layer. Thesystem is always in the replication layer. To create partnerships, a system must be in replication layer.
A Lenovo V series family system is in the storage layer by default, but the system can be configured to be in the replication layer instead.