Array configurations

An array is an ordered configuration, or group, of physical devices (disk drive or flash drive modules) that is used to define logical volumes or devices. An array is a type of MDisk that is made up of disk drives; these drives are members of the array. A Redundant Array of Independent Disks (RAID) is a method of configuring member drives to create high availability and high performance systems.

The system supports nondistributed and distributed array configurations. In nondistributed arrays, entire drives are defined as "hot-spares". Hot-spare drives are idle and do not process I/O for the system until a drive failure occurs. When a member drive fails, the system automatically replaces the failed drive with a hot-spare drive. The system then resynchronizes the array to restore its redundancy. However, all member drives within a distributed array have a rebuild area that is reserved for drive failures. All the drives in an array can process I/O data and provide faster rebuild times when a drive fails. The RAID level provides different degrees of redundancy and performance; it also determines the number of members in the array.

If encryption is enabled on your system, you can create encrypted arrays and distributed arrays. For information, see Configuring encryption.

Figure 1 shows the relationships of the array components on the system.

Figure 1. Array objects
This image shows an overview of RAID objects

Arrays

A non-distributed array can contain 2 - 16 drives; several arrays create the capacity for a pool. For redundancy, spare drives ("hot spares") are allocated to assume read/write operations if any of the other drives fail. The rest of the time, the spare drives are idle and do not process requests for the system. When a member drive fails in the array, the data can only be recovered onto the spare as fast as that drive can write the data. Because of this bottleneck, rebuilding the data can take many hours as the system tries to balance host and rebuild workload. As a result, the load on the remaining member drives can significantly increase. The latency of I/O to the rebuilding array is affected for this entire time. Because volume data is striped across MDisks, all volumes are affected during the time it takes to rebuild the drive.

Distributed arrays

Lenovo Storage V series nodes also support distributed arrays. Distributed array configurations create large-scale internal MDisks. These arrays, which can contain 4 - 128 drives, also contain rebuild areas that are used to maintain redundancy after a drive fails. If not enough drives are available on the system (for example, in configurations with fewer than four flash drives), you cannot configure a distributed array.

Array configuration guidelines

After system setup, you must configure storage by creating pools and assigning storage to specific pools. Ensure that a pool or pools have been created before assigning storage. In the management GUI, select Pools > Actions > Add Storage.

Use the lsarrayrecommendation command to display the system recommendations for configuring an array. For greatest control and flexibility, you can use the mkarray command-line interface (CLI) command to configure a nondistributed array on your system. To configure a distributed array, you can use the mkdistributedarray command.