The Universal Unique Identifier (UUID) must be updated
when the system board is replaced. Use the Advanced Settings Utility
to update the UUID in the UEFI-based server.
The ASU is an online tool that supports several operating
systems. Make sure that you download the version for your operating
system. You can download the ASU from the IBM website. To download
the ASU and update the UUID, go to the IBM Advanced Settings Utility (ASU) website.
- ASU sets the UUID in the Integrated Management Module (IMM).
Select one of the following methods to access the Integrated Management
Module (IMM) to set the UUID:
- Online from the target system (LAN or keyboard console style (KCS)
access)
- Remote access to the target system (LAN based)
- Bootable media containing ASU (LAN or KCS, depending upon the
bootable media)
- Copy and unpack the ASU package, which also includes other
required files, to the server. Make sure that you unpack the ASU and
the required files to the same directory. In addition to the application
executable (asu or asu64), the following files are required:
- For Windows based operating systems:
- ibm_rndis_server_os.inf
- device.cat
- For Linux based operating systems:
- After you install ASU, use the following command syntax
to set the UUID:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
[access_method]
Where:
- <uuid_value>
- Up to 16-byte hexadecimal value assigned by you.
- [access_method]
- The access method that you selected to use from the following
methods:
- Online authenticated LAN access, type the command:
[host <imm_internal_ip>] [user <imm_user_id>][password <imm_password>]
Where:
- imm_internal_ip
- The IMM internal LAN/USB IP address. The default value is 169.254.95.118.
- imm_user_id
- The IMM account (1 of 12 accounts). The default
value is USERID.
- imm_password
- The IMM account password (1 of 12 accounts). The default value
is PASSW0RD (with a zero 0 not an O).
Note: If you do not specify any of these parameters,
ASU will use the default values. When the default values are used
and ASU is unable to access the IMM using the online authenticated
LAN access method, ASU will automatically use the unauthenticated
KCS access method.
The following commands are examples of
using the userid and password default values and not using the default
values:
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --user <user_id>
--password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
- Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for access_method when
you use this access method.
Example:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
The
KCS access method uses the IPMI/KCS interface. This method requires
that the IPMI driver be installed. Some operating systems have the
IPMI driver installed by default. ASU provides the corresponding mapping
layer. See IBM Advanced Settings Utility program or the Advanced
Settings Utility Users Guide for more details.
- Remote LAN access, type the command:
Note: When using the remote LAN access method to access IMM using
the LAN from a client, the host and the imm_external_ip address
are required parameters.
host <imm_external_ip> [user <imm_user_id>][password <imm_password>]
Where:
- imm_external_ip
- The external IMM LAN IP address. There is no default value. This
parameter is required.
- imm_user_id
- The IMM account (1 of 12 accounts). The default
value is USERID.
- imm_password
- The IMM account password (1 of 12 accounts). The default value
is PASSW0RD (with a zero 0 not an O).
The following commands are examples of using the
userid and password default values and not using the default values:
Example that does not use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --host <imm_ip>
--user <user_id> --password <password>
Example that does use the userid and password default values:
asu set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value> --host <imm_ip>
- Bootable media:
You can also build a bootable media using the applications available
through the Tools Center website at the IBM ToolsCenter website.
From the left pane, click IBM System x and BladeCenter
Tools Center, then click Tool reference for
the available tools.
- Restart the server.