A Uncorrectable Bus Error has occurred on system [ComputerSystemElementName]. (DIMMs)
This message is for the use case when an implementation has detected a
Bus Uncorrectable Error.
May also be shown as
806f08132581xxxx or 0x806f08132581xxxx
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0240
Automatically Notify Support
Yes
User Response
1. Check the system-event log.
2. (Trained technician only) Remove the failing microprocessor from the system board (see Removing a
microprocessor and heat sink).
3. Check for a server firmware update.
Important: Some cluster solutions require specific code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Make sure that the two microprocessors are matching.
5. (Trained technician only) Replace the system board.