Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (PCI 1)
This message is for the use case when an implementation has detected a
Fault in a slot.
May also be shown as
806f00213001xxxx or 0x806f00213001xxxx
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0330
Automatically Notify Support
Yes
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware.
Important: Some cluster solutions require specific code levels or coordinated code updates.
If the device is part of a cluster solution, verify that the latest level of code is supported for
the cluster solution before you update the code.
4. Remove both adapters.
5. Replace the riser cards.
6. (Trained service technicians only) Replace the system board.
PCI 2 :
PCI 5 :