[ProcessorElementName] has Failed with IERR. (CPU 1)
This message is for the use case when an implementation has detected a
Processor Failed - IERR Condition.
May also be shown as
806f00070301xxxx or 0x806f00070301xxxx
Alert Category
Critical - CPU
CIM Information
Prefix:PLAT
and ID:0042
Automatically Notify Support
No
User Response
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS.
Important: Some cluster solutions require specific code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
2. Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
3. Run the DSA program.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained technician only) Replace microprocessor n.
7. (Trained technician only) Replace the system board. (n = microprocessor number)