Sensor [SensorElementName] has transitioned to critical from a less severe state. (No I/O Resources)
This message is for the use case when an implementation has detected a
Sensor transitioned to critical from less severe.
May also be shown as
8007020f2582xxxx or 0x8007020f2582xxxx
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0522
Automatically Notify Support
No
User Response
Complete the following steps for PCI I/O resource error issue resolution:
1. Understand the I/O resource requirements in a basic system.
2. Identify the I/O resource requirements for desired add-in adapters. For examples, PCI-X or PCIe adapters.
3. Disable on-board devices that you can do without and that request I/O.
4. In F1 setup, select the System Settings then Device and I/O Ports menu.
5. Remove adapters or disable slots until the I/O resource is less than 64 KB.