Check whether there are rubber stoppers come with your
PCI riser-card assembly 2. If there are rubber stoppers come with
your PCI riser-card assembly 2, skip to next step.
There are two kinds of rubber stoppers. Attach the two
rubber stoppers on PCI riser-card assembly 2, along the edges of the
pin holes, as shown in the following illustration.
Figure 1. Rubber stoppers installation
Attach the bigger rubber stopper near the latch of PCI
riser-card assembly 2.
Attach the smaller rubber stopper near the pin hole
of PCI riser-card assembly 2.
Note: You can purchase the miscellaneous parts kit (FRU part
number 94Y7571) to acquire three sets of rubber stoppers. Keep additional
rubber stoppers for potential future use.
Install the adapter in the new PCI riser-card assembly
(see Replacing an adapter).
Set any jumpers or switches on the adapter as directed
by the adapter manufacturer.
Remove the PCI filler panel, if one is present, from the
rear of the server.
Align the PCI riser-card assembly with the PCI riser connector
on the system board; then, press down firmly until the PCI riser-card
assembly is seated correctly in the connector on the system board.
Note: Support the server from the middle of the rear chassis
when installing PCI riser-card assembly 2.