Use this information to install a memory module.
- Read the safety information that begins on Safety and Installation guidelines.
- Turn off the server and peripheral devices and disconnect
the power cords and all external cables, if necessary.
- Remove the cover (see Removing the cover).
- Remove the air baffle (see Removing the air baffle).
- Carefully open the retaining clips on each end of the DIMM
connector and remove the DIMM.
Attention: To avoid breaking the retaining clips
or damaging the DIMM connectors, open and close the clips gently.
Figure 1. DIMM removal
- Touch the static-protective package that contains the DIMM
to any unpainted metal surface on the outside of the server. Then,
remove the DIMM from the package.
- Turn the DIMM so that the alignment slot align correctly
with the alignment tab.
- Insert the DIMM into the connector by aligning the edges
of the DIMM with the slots at the ends of the DIMM connector (see System-board optional-device connectors for the locations
of the DIMM connectors).
- Firmly press the DIMM straight down into the connector
by applying pressure on both ends of the DIMM simultaneously. The
retaining clips snap into the locked position when the DIMM is firmly
seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips,
the DIMM has not been correctly inserted; open the retaining clips,
remove the DIMM, and then reinsert it.