Carefully open the retaining clips on each end of the DIMM
connector and remove the DIMM.
Attention: To avoid breaking the retaining clips
or damaging the DIMM connectors, open and close the clips gently.
Figure 1. DIMM installation
Touch the static-protective package that contains the DIMM
to any unpainted metal surface on the outside of the server. Then,
remove the DIMM from the package.
Turn the DIMM so that the alignment slot align correctly
with the alignment tab.
Insert the DIMM into the connector by aligning the edges
of the DIMM with the slots at the ends of the DIMM connector (see System-board optional-device connectors for the locations
of the DIMM connectors).
Firmly press the DIMM straight down into the connector
by applying pressure on both ends of the DIMM simultaneously. The
retaining clips snap into the locked position when the DIMM is firmly
seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips,
the DIMM has not been correctly inserted; open the retaining clips,
remove the DIMM, and then reinsert it.
Reconnect the power cords and any cables that you removed.