Microprocessor (depending on the model):
- Supports up to two multi-core microprocessors (one installed)
- Level-3 cache
- Two QuickPath Interconnect (QPI) links speed up to 8.0 GT per
second
Note:
- Use the Setup utility program to determine the type and speed
of the microprocessors.
- For a list of supported microprocessors, see the Lenovo ServerProven website.
|
Memory (depending on the model):
- Minimum: 2 GB
- Maximum: 768 GB
- 64 GB using unbuffered DIMMs (UDIMMs)
- 384 GB using registered DIMMs (RDIMMs)
- 768 GB using load reduction DIMMs (LRDIMMs)
- Type:
- PC3-8500 (DDR3-1066), PC3-10600 (DDR3-1333), PC3-12800 (DDR3-1600),
or PC3-14900 (DDR3-1866)
- Single-rank, dual-rank, or quad-rank
- Registered DIMM (RDIMM), unbuffered DIMM (UDIMM), or load reduced
DIMM (LRDIMM)
- Slots: 24 dual inline
- Supports (depending on the model):
- 4 GB UDIMM
- 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs
- 32 GB LRDIMM
|
SATA optical drives (optional for 2.5-inch
models):
Hard disk drive expansion bays (depending on the model):
- 2.5-inch models: Up to eight 2.5-inch hot-swap SAS/SATA hard disk
drive bays (with an optional optical drive bay)
- 3.5-inch models: Up to three 3.5-inch hot-swap SAS/SATA or simple-swap
SATA hard disk drive bays
Attention:
- As a general consideration, do not mix standard 512-byte and advanced
4-KB format drives in the same RAID array because it may lead to potential
performance issues.
PCI expansion slots:
Supports two PCI
riser slots:
- Slot 1 supports low-profile cards.
- Slot 2 supports half-length, full-height cards.
- PCI Express 3.0 x8
- PCI Express 3.0 x16 (two microprocessors installed)
- PCI-X 64-bit/133 MHz
|
Video controller (integrated into IMM2):
Hot-swap fans:
- One microprocessor: 4 dual-motor hot-swap fans.
- Two microprocessors: 6 dual-motor hot-swap fans.
Power supply:
- Up to two hot-swap power supplies for redundancy support
- 550-watt ac
- 750-watt ac
- 750-watt dc
Note: Power supplies in the server must be with the same power
rating or wattage.
|
Integrated functions:
- Integrated Management Module II (IMM2), which consolidates multiple
management functions in a single chip.
- Intel I350AM4 Quad Port Gigabit Ethernet controller with Wake
on LAN support
- Eight Universal Serial Bus (USB) ports for 3.5-inch models. Seven
Universal Serial Bus (USB) ports for 2.5-inch models. One port is
for optional USB flash device with embedded hypervisor software is
installed.
- Six network ports (four 1 Gb Ethernet ports on the system board
and two additional ports when the optional Dual-Port 10 Gb Network
Adapter is installed)
- One System Management 1 Gb Ethernet port on the rear connected
to a systems management network. This system management connector
is dedicated to the IMM2 functions.
- One serial port
|
RAID controllers (depending on the model):
- A ServeRAID H1110 SAS/SATA adapter that provides RAID 0, 1, and
10.
- A ServeRAID M1115 SAS/SATA adapter that provides RAID 0, 1, and
10 with optional FoD RAID 5/50 and SED (Self Encrypting Drive) upgrade.
- A ServeRAID M5110 SAS/SATA adapter that provides RAID 0, 1, and
10. Optional upgrade:
- RAID 5/50 (512 MB Cache) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (512 MB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (1 GB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 and SED (Zero Cache)
- A ServeRAID M5120 SAS/SATA adapter that provides RAID 0, 1, and
10. Optional upgrade:
- RAID 5/50 (512 MB Cache) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (512 MB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (1 GB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 and SED (Zero Cache)
|
Environment: compliant with ASHRAE
class A3 specifications.
Server on:
- Temperature:
- 5°C to 40°C (41°F to 104°F)
- Altitude: 0 to 950 m (3,117 ft); decrease the maximum system temperature
by 1°C for every 175-m increase in altitude.
- Maximum altitude: 3,050 m (10,000 ft), 5°C to 28°C (41°F to 82.4°F)
- Humidity:
- Non-condensing: -12°C dew point (10.4°F)
- Relative humidity: 8% to 85%
- Maximum dew point: 24°C (75.2°F)
- Maximum rate of temperature change:
- Tape drives: 5°C/hr (41°F/hr)
- Hard disk drives: 20°C/hr (68°F/hr)
Server off:
- Temperature: 5°C to 45°C (41°F to 113°F)
- Relative humidity: 8% to 85%
- Maximum dew point: 27°C (80.6°F)
Storage (non-operating):
- Temperature: 1°C to 60°C (33.8°F to 140°F)
- Maximum altitude: 3,050 m (10,000 ft)
- Relative humidity: 5% to 80%
- Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):
- Temperature: -40°C to 60°C (-40°F to 140°F)
- Maximum altitude: 10,700 m (35,105 ft)
- Relative humidity: 5% to 100%
- Maximum dew point: 29°C (84.2°F)
|
Particulate contamination: airborne particulates
and reactive gases acting alone or in combination with other environmental
factors such as humidity or temperature might pose a risk to the server.
For information about the limits for particulates and gases, see Particulate contamination.
Attention:
- Design to ASHRAE Class A3, ambient of 40°C, with relaxed support:
- Support cloud like workload with no performance degradation acceptable
(Turbo-Off)
- Under no circumstance, can any combination of worst case workload
and configuration result in system shutdown or design exposure at
40°C
- Specific microprocessors supported environment:
- Microprocessor Intel Xeon E5-2690, 135W:
- Temperature: 10°C to 27°C (50°F to 80.6°F)
- Altitude: 0 to 304.8 m (1,000 ft)
- Microprocessor models with 115W and 130W:
- Temperature: 10°C to 35°C (50°F to 95°F)
- Altitude: 0 to 914.4 m (3,000 ft)
Size:
- 1U
- Height: 43 mm (1.7 inches)
- Depth: 734 mm (28.9 inches)
- Width: 429 mm (16.9 inches)
- Weight: approximately 16.4 kg (36.16 lb) when fully configured
Acoustical noise emissions:
- Sound power, idling: 6.5 bels maximum
- Sound power, operating: 6.5 bels maximum
|
Heat output:
Approximate heat
output:
- Minimum configuration: 461 Btu per hour (AC 135 watts)
- Maximum configuration: 3378 Btu per hour (AC 990 watts)
Electrical input:
- Sine-wave input (50 - 60 Hz) required
- Input voltage low range:
- Minimum: 100 V ac
- Maximum: 127 V ac
- Input voltage high range:
- Minimum: 200 V ac
- Maximum: 240 V ac
- Input kilovolt-amperes (kVA), approximately:
- Minimum: 0.14 kVA
- Maximum: 0.993 kVA
Note:
- Power consumption and heat output vary depending on the number
and type of optional features installed and the power-management optional
features in use.
- The noise emission level stated is the declared (upper limit)
sound power level, in bels, for a random sample of machines. All measurements
are made in accordance with ISO 7779 and reported in conformance with
ISO 9296. Actual sound-pressure levels in a given location might
exceed the average values stated because of room reflections and other
nearby noise sources. The noise emission level stated in the declared
(upper limit) sound-power level, in bels, for a random sample of system.
|