Replacing the power interposer card assembly

Use this information to replace the power interposer card assembly.

To install the power interposer card assembly, complete the following steps:

  1. Read the safety information that begins in Safety and Installation guidelines.
  2. Reconnect the power cable to the power interposer card.
  3. Align the screw holes on the power interposer card with the screw holes on the chassis; then, install the screws to secure the power interposer card to the chassis.
    Figure 1. Power interposer card assembly installation
    Power interposer card assembly installation
    Figure 2. Power interposer card assembly installation (with advanced remote battery holder)
    Power interposer card assembly installation (with advanced remote battery holder)
  4. Orient the safety cover as shown in the above illustration and align the screws with the screw holes on the power interposer card. Tighten the screws to secure the safety cover on the power interposer card.
  5. Reconnect the power cables to the connectors on the system board and secure the power cables with any cable clips on the chassis.
  6. Reconnect the power cable from the RAID battery on the safety cover to the ServeRAID adapter, if you have removed it.
  7. Reinstall PCI riser-card assembly 2, if you removed it (see Replacing a PCI riser-card assembly).
  8. Reinstall the air baffle (see Replacing the air baffle).
  9. Reinstall the cover (see Replacing the server top cover).
  10. Reconnect the power cords and any cables that you removed.
  11. Turn on the peripheral devices and the server.