Microprocessor (depending on the model):
- Supports one Intel Pentium 1400 series microprocessor or up to
two Intel Xeon™ EN E5-2400 series microprocessors
- Up to 20 MB Level-3 cache
- One QuickPath Interconnect (QPI) link speed up to 8 Giga Transfers
(GT) per second
- Scalable up to eight cores
- Three memory channels per microprocessor on the system board that
supports two DIMMs per channel
|
Memory (depending on the model):
- Slots: 12 dual inline memory module connectors
- Minimum: 2 GB
- Maximum: up to 192 GB
- Type: DDR3-1066 (PC3-8500), DDR3-1333 (PC3-10600), or DDR3-1600
(PC3-12800), ECC, single-rank or dual-rank, DDR3 registered or unbuffered
SDRAM DIMMs
- Supports:
- UDIMM: 4 GB
- RDIMM: 2 GB, 4 GB, 8 GB, 16 GB, or 32 GB (when available)
|
Drive expansion bays (depending on the
model):
- The server can support up to eight 2.5-inch drives or up to four
3.5-inch drives. The following drives are supported:
- 2.5-inch hot-swap SAS/SATA hard disk drive
- 2.5-inch simple-swap SATA or solid-state hard disk drive
- 3.5-inch hot-swap SAS/SATA hard disk drive
- 3.5-inch simple-swap SATA hard disk drive
Attention: As a general consideration, do not mix
standard 512-byte and advanced 4-KB format drives in the same RAID
array because it might lead to potential performance issues.
Note: For specific models that may be shipped initially with four
hard disk drives, configuration may be able to expand to eight hard
disk drives via Features on Demand (FoD).
|
Optional SATA optical drives (depending
on your model):
Fans:
- The server comes standard with four speed-controlled fans for
one-microprocessor configuration
- Supports up to six fans with two microprocessors installed
PCI expansion slots (depending on your model):
- Two x8 low-profile, PCIE 3.0 adapter slots on the system board
- One x16 (x16 mechanically) PCIE 3.0 adapter slot
- One x4 (x8 mechanically) PCIE 3.0 adapter slot on the optional
PCI riser-card for an optional RAID adapter
|
Integrated functions:
- Integrated Management Module II (IMM2), which provides service
processor control and monitoring functions, video controller, and
remote keyboard, video, mouse, and remote hard disk drive capabilities
- Onboard Intel Powerville 4-port Gigabit Ethernet controller with
Wake on LAN support (by default Ethernet 1 and 2 are enabled, to enable
Ethernet 3 and 4, it is done through the Features on Demand (FoD))
- Onboard PCH with LSI software RAID with support for RAID levels
0, 1 and 10
- Light path diagnostics
- Seven Universal Serial Bus (USB) 2.0 ports:
- Two on the front of the chassis
- Four on the rear of the chassis
- One internal
- One serial port
Note: In messages and documentation, the term service
processor refers to the integrated management module II (IMM2).
|
Power supply (depending
on your model):
- One fixed 460-watt ac power supply
- Up to two 460-watt or 675-watt ac hot-swap power supplies for
1+1 redundancy support
- Up to two 675-watt dc
Video controller (integrated into IMM, depending on
your model):
|
RAID controllers:
The following
RAID options are available for the server:
- ServeRAID H1110 SAS/SATA Controller for System x
- ServeRAID M1115 SAS/SATA Controller for System x
- ServeRAID M5110 SAS/SATA Controller for IBM System x
- ServeRAID M5120 SAS/SATA Controller for IBM System x
- ServeRAID M5100 Series Battery Kit for IBM System x
- ServeRAID M5100 Series 512MB Cache/RAID 5 Upgrade for IBM System
x
- ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for IBM System
x
- ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade for IBM System
x
- ServeRAID M5100 Series 1GB Flash/RAID Upgrade for IBM System x
- ServeRAID C105 for IBM System X
Size:
- Height: 43 mm ( 1.7 inches, 1U)
- Depth: 673.1 mm (26.5 inches)
- Width: 447 mm (17.6 inches)
- Maximum weight: 15.8 kg (33.8 lb) when fully configured
Acoustical noise emissions:
- Sound power, idling: 6.5 bels
- Sound power, operating: 6.5 bels
|
Environment:
- Air temperature:
- Server on: 5°C to 40°C (41°F to 104°F); altitude: 0 to 915 m (3000
ft)
- Server on: 5°C to 32°C (41°F to 89.6°F); altitude: 915 m (3000
ft) to 2134 m (7000 ft)
- Server on: 5°C to 28°C (41°F to 82.4°F); altitude: 2134 m (7000
ft) to 3050 m (10000 ft)
- Server off: 5°C to 45°C (41° to 113°F)
- Shipment: -40°C to +60°C (-40°F to 140°F)
- Humidity:
- Server on: 8% to 85%; maximum dew point: 24°C (75.2°F); maximum
rate of change 5 °C/hr
- Server off: 8% to 80%; maximum dew point: 27°C (80°F)
- Shipment: 5% to 100%
- Design to ASHRAE Class A3:
- Ambient of 35°C to 40°C (95°F to 104°F), with relaxed support
- Support cloud like workload with no performance degradation acceptable
(Turbo-Off)
- Under no circumstance, can any combination of worst case workload
and configuration result in system shutdown or design exposure at
40°C (104°F)
- Particulate contamination:
Attention: Airborne
particulates and reactive gases acting alone or in combination with
other environmental factors such as humidity or temperature might
pose a risk to the server. For information about the limits for particulates
and gases, see Particulate contamination.
|
Heat output:
Approximate heat output:
- Minimum configuration: 406 Btu per hour (119 watts)
- Maximum configuration: 2627.3 Btu per hour (770 watts)
Electrical input:
- Sine-wave input (50 - 60 Hz) required
- Input voltage automatically selected
- Input voltage low range:
- Minimum: 100 V ac
- Maximum: 127 V ac
- Input voltage high range:
- Minimum: 200 V ac
- Maximum: 240 V ac
- Input kilovolt-amperes (kVA), approximately:
- Minimum: 0.12 kVA
- Maximum: 0.78 kVA
Note:
- Power consumption and heat output vary depending on the number
and type of optional features installed and the power-management optional
features in use.
- The noise emission level stated is the declared (upper limit)
sound power level, in bels, for a random sample of machines. All
measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296.
|