Installing a USB embedded hypervisor flash device

To install a USB embedded hypervisor flash device, do the following:

  1. Turn off the server. Then, disconnect all external cables and remove all peripheral devices.
  2. Remove the server cover. See Removing the server cover.
  3. Remove the air baffle. See Removing the air baffle.
  4. Remove the PCI riser-card assembly. See Removing the PCI riser-card assembly.
  5. Locate the USB embedded hypervisor flash device connector on the system board. See System-board connectors.
  6. Align the USB flash device with the connector on the system board and push it into the connector until it is firmly seated. Then, slide the lock bar on the flash device connector to the locked position.
    Figure 1. USB embedded hypervisor flash device installation
    USB embedded hypervisor flash device installation

  7. Complete the parts replacement. See Completing the parts replacement.