Use this information to remove the bezel.
Read the safety information in Safety and Installation guidelines.
If you are replacing a server component in the server,
you need to turn off the server and peripheral devices, and disconnect
the power cords and all external cables.
To remove the bezel, complete the following steps.
- If the server has been installed in a rack, press the two
release latches on the front of the server and remove the server out
of the rack enclosure.
Attention: Two or more people are required to remove
the server from a rack cabinet.
- Turn off the server and all peripheral devices, and disconnect
the power cords and all external cables.
- Remove the server top cover (see Removing the cover).
- From inside the server, press the bezel release latch toward
the left side of the server.
- Pivot the bezel forward and pull it away from the server.
Figure 1. Bezel removal
If you are instructed to return the server component
or optional device, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Attention: For proper cooling and airflow, replace
the bezel and server cover before you turn on the server.