库存信息电子邮件提供有关系统的硬件组件和配置的概述。当相关的软件更新可用或者发现可能影响您的配置的问题时,服务人员可使用此信息来与您取得联系。建议您最好是启用库存报告。
因为库存信息是使用自动通报电子邮件功能发送的,所以必须首先满足自动通报功能需求并启用自动通报电子邮件功能,然后才能尝试发送库存信息电子邮件。您可以调整联系人信息,调整库存电子邮件的发送频率,也可以使用管理 GUI 或命令行界面手动发送库存电子邮件。
回拨功能可以向支持中心发送包含特定配置信息的增强报告。支持中心可以使用此信息自动生成基于您实际配置的建议。
库存信息电子邮件的示例 显示电子邮件示例。有关您系统的回拨库存中所 包含特定信息的详细信息,请配置系统以向您自己发送库存电子邮件。电子邮件标题包含文本 Spectrum Virtualize Error Notification (cluster),其中 cluster 是您的系统名称。
# Timestamp = Sun Mar 18 12:09:16 2018 # Timezone = +0000, UTC # Organization = # Machine Address = # Machine City = # Machine State = XX # Machine Zip = # Machine Country = # Contact Name = lens # Alternate Contact Name = N/A # Contact Phone Number = 12357 # Alternate Contact Phone Number = N/A # Offshift Phone Number = N/A # Alternate Offshift Phone Number = N/A # Contact Email = developer@system.com # Machine Location = town # Machine Type = 2076524 # Serial Number = 7836531 # Machine Part Number = # System Version = 9.9.9 (build 140.12.0000000000000) # Record Type = 6 # Frequency = 0 # Cluster Alias = 0x10036600202 # IBM Customer Number = # IBM Component ID = # IBM Country Code = # Spectrum Virtualize Unique ID = 10036800202 # Cluster_VPD: id:0000010036600202 name:mcr-fab1-cluster-29 location:local partnership: bandwidth: total_mdisk_capacity:3.2TB space_in_mdisk_grps:3.2TB space_allocated_to_vdisks:1001.00GB total_free_space:2.3TB statistics_status:on statistics_frequency:1 required_memory:32768 cluster_locale:en_US time_zone:522 UTC code_level:9.9.9 (build 140.12.0000000000000) FC_port_speed:2Gb id_alias:0000010036600202 gm_link_tolerance:300 gm_inter_cluster_delay_simulation:0 gm_intra_cluster_delay_simulation:0 email_reply:stevenfr@system.com email_contact:lens email_contact_primary:12357 email_contact_alternate: email_contact_location:town email_state:running inventory_mail_interval:0 total_vdiskcopy_capacity:1001.00GB total_used_capacity:1001.00GB total_overallocation:30 total_vdisk_capacity:1001.00GB iscsi_auth_method:none auth_service_configured:no auth_service_enabled:no auth_service_pwd_set:no auth_service_cert_set:no relationship_bandwidth_limit:25gm_max_host_delay:5 tier:tier0_flash tier_capacity:0.00MB tier_free_capacity:0.00MB tier:tier1_flash tier_capacity:0.00MB tier_free_capacity:0.00MB tier:tier_enterprise tier_capacity:3.23TB tier_free_capacity:2.26TB tier:tier_nearline tier_capacity:0.00MB tier_free_capacity:0.00MB email_contact2: email_contact2_primary: email_contact2_alternate: total_allocated_extent_capacity:1001.00GB has_nas_key:no auth_service_type:tip layer:storage rc_buffer_size:48 cache_prefetch:on email_organization: email_machine_address: email_machine_city: email_machine_state:XX email_machine_zip: email_machine_country: high_temp_mode:off # End # Cluster_Size: Number of Nodes in Cluster: 2 # Node_VPD: id 1 system board: 24 fields part_number 31P1843 system_serial_number 11S31P1842YM14BG42V01C number_of_processors 1 number_of_memory_modules 4 number_of_fans 0 number_of_generic_devices 1 number_of_FC_adapters 1 number_of_Ethernet_adapters 1 number_of_SAS_adapters 1 number_of_Bus_adapters 1 number_of_IB_adapters 0 number_of_power_supplies 0 number_of_local_managed_disks 0 BIOS_manufacturer American Megatrends Inc. BIOS_version FABFD010 BIOS_release_date 09/17/2014 system_manufacturer IBM system_product FAB1 Controller planar_manufacturer IBM CMOS_battery_part_number 33F8354 frame_assembly_part_number N/A power_cable_assembly_part_number N/A service_processor_firmware disk_controller 31P1843 processor: 6 fields part_number 31P1843 processor_location 1 manufacturer Intel version Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz speed 1901 status Enabled memory module: 24 fields part_number 64P8453 device_location Node0_Dimm0 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 383806D6 part_number 64P8453 device_location Node0_Dimm1 bank_location Node0_Bank0 size (MB) 8192 manufacturer Hynix Semiconducto serial_number 3009368E part_number 64P8453 device_location Node0_Dimm2 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 38380628 part_number 64P8453 device_location Node0_Dimm3 bank_location Node0_Bank0 size (MB) 8192 manufacturer Hynix Semiconducto serial_number 3008F2BE Adapter card: 27 fields card_type SAS part_number 31P1843 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer PMC-Sierra Inc. device SPCve 16x12G SAS card_revision Unknown chip_revision 1.2 card_type Bus part_number 31P1843 port_numbers 1 location 0 device_serial_number Unknown manufacturer PLX Technology, Inc. device PCIe Gen3 Switch card_revision Unknown chip_revision 50.2 card_type Ethernet part_number 31P1843 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Intel Corporation device I350 Ethernet card_revision Unknown chip_revision 0.1 Ethernet port: 33 fields part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 1 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 2 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 3 Adapter card: 18 fields card_type Compression part_number 31P1861 port_numbers 1 location 1 device_serial_number Unknown manufacturer Intel Corporation device Compression card_revision Unknown chip_revision Unknown card_type FC part_number 64P8473 port_numbers 1 2 3 4 location 2 device_serial_number 11S00MJ028YM10MY57F00V manufacturer IBM device QE8 8G FC card_revision 3 chip_revision 2.0 Fibre channel port: 44 fields part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF26EL1VF supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 1 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF26EL1VE supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 2 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF26EL1YG supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 3 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF26EL1VG supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 4 device: 8 fields part_number 31P1843 bus sata device 0 model SanDisk SD6SA1M064G revision X231600 serial_number SD6SA1M0140263401463 approx_capacity 59 hw_revision system code level: 4 fields id 1 node_name node1 WWNN 00000000000000BA code_level 9.9.9 (build 140.12.0000000000000) front panel assembly: 3 fields part_number N/A front_panel_id 01-1 dump_name 7836531-1 # End # Node_VPD: id 2 system board: 24 fields part_number 31P1843 system_serial_number 11S31P1842YM14BG42V00K number_of_processors 1 number_of_memory_modules 4 number_of_fans 0 number_of_generic_devices 1 number_of_FC_adapters 1 number_of_Ethernet_adapters 1 number_of_SAS_adapters 1 number_of_Bus_adapters 1 number_of_IB_adapters 0 number_of_power_supplies 0 number_of_local_managed_disks 0 BIOS_manufacturer American Megatrends Inc. BIOS_version FABFD010 BIOS_release_date 09/17/2014 system_manufacturer IBM system_product FAB1 Controller planar_manufacturer IBM CMOS_battery_part_number 33F8354 frame_assembly_part_number N/A power_cable_assembly_part_number N/A service_processor_firmware disk_controller 31P1843 processor: 6 fields part_number 31P1843 processor_location 1 manufacturer Intel version Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz speed 1901 status Enabled memory module: 24 fields part_number 64P8453 device_location Node0_Dimm0 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 38380553 part_number 64P8453 device_location Node0_Dimm1 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 3838068E part_number 64P8453 device_location Node0_Dimm2 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 378028D3 part_number 64P8453 device_location Node0_Dimm3 bank_location Node0_Bank0 size (MB) 8192 manufacturer Micron serial_number 37802934 Adapter card: 27 fields card_type SAS part_number 31P1843 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer PMC-Sierra Inc. device SPCve 16x12G SAS card_revision Unknown chip_revision 1.2 card_type Bus part_number 31P1843 port_numbers 1 location 0 device_serial_number Unknown manufacturer PLX Technology, Inc. device PCIe Gen3 Switch card_revision Unknown chip_revision 50.2 card_type Ethernet part_number 31P1843 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Intel Corporation device I350 Ethernet card_revision Unknown chip_revision 0.1 Ethernet port: 33 fields part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 1 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 2 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 3 Adapter card: 18 fields card_type Compression part_number 31P1861 port_numbers 1 location 1 device_serial_number Unknown manufacturer Intel Corporation device Compression card_revision Unknown chip_revision Unknown card_type FC part_number 64P8473 port_numbers 1 2 3 4 location 2 device_serial_number 11S00MJ028YM10MY57F0EY manufacturer IBM device QE8 8G FC card_revision 3 chip_revision 2.0 Fibre channel port: 44 fields part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF25EL2FN supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 1 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF25EL2M1 supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 2 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF25EL2G1 supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 3 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CF25EL2FP supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 4 device: 8 fields part_number 31P1843 bus sata device 0 model SV9SLM6B120GLM21 revision FW1141 serial_number SV9SLM6B120GLM21SPG170604JH approx_capacity 55 hw_revision system code level: 4 fields id 2 node_name node2 WWNN 00000000000000BA code_level 9.9.9 (build 140.12.0000000000000) front panel assembly: 3 fields part_number N/A front_panel_id 01-2 dump_name 7836531-2 # End # License_Information: used_flash 0.00 used_remote 0.00 used_virtualization 0.00 license_flash 0 license_remote 0 license_virtualization 0 license_physical_disks 0 license_physical_flash off license_physical_remote off used_compression_capacity 0.00 license_compression_capacity 0 license_compression_enclosures 0 license_easy_tier 0 license_cloud_enclosures 0 scu_ratio_flash 1.00 scu_ratio_enterprise 1.18 scu_ratio_nearline 4.00 # End # Controller_Information: Number of Controllers in Cluster: 0 # End # Host_Information: Number of Hosts connected to the Cluster: 2 Host Details: Host Id FC Ports iSCSI Ports SAS Ports 0 4 0 0 1 5 0 0 # End # Enclosure_Information: Number of Enclosures in the Cluster: 1 Enclosure Details: Model Type Serial Number FRU Part Number FRU Identity 2076-524 7836531 31P1854 11S31P1857YM11BG42N020 # End # RAID_Information: Number of RAID Arrays in the Cluster: 1 Number of Distributed RAID Arrays in the Cluster: 0 Maximum drive count in a Distributed RAID Array: 0 Maximum rebuild areas in a Distributed RAID Array: 0 RAID Details: Raid Level Number of Disks Capacity in TB Raid0 0 0 Raid1 0 0 Raid5 0 0 Raid6 1 3 Raid10 0 0 DRaid5 0 0 DRaid6 0 0 # End # Drive_Information: Number of Drives in the Cluster: 7 Drive Details: Use Product Id FRU PN FRU Identity FW Level member HUC101890CS420 00RX929 11S00FJ044YXXX04G0ANRH J5H6 member HUC101890CS420 00RX929 11S00FJ044YXXX04G0ALSH J5H6 member HUC101890CS420 00RX929 11S00FJ044YXXX04G0B47H J5H6 member HUC101890CS420 00RX929 11S00FJ044YXXX04G0B39H J5H6 member HUC101890CS420 00RX929 11S00FJ044YXXX04G0A93H J5H6 member HUC101890CS420 00RX929 11S00FJ044YXXX04G0AXYH J5H6 failed HUC101890CS420 00RX929 11S00FJ044YXXX04G0B3LH J5H3 # End # MDisk_Information: Number of MDisks in the Cluster: 1 MDisk Details: Mode Number of MDisks Max Size Internal 0 0 GB External 1 3316 GB # End # Easy_Tier_Information: Number of MDiskGrps in the Cluster: 1 Easy Tier Details: MDiskGrp Id SSD Disks SSD Capacity Enterprise Disks Enterprise Capacity Nearline Disks Nearline Capacity 0 0 0 0 0 0 0.00MB Number of Easy Tier MDiskGrps in the Cluster: 1 # End # VDisk_Information: Number of VDisks in the Cluster: 1001 VDisk Details: IO Group Number of VDisks Max Size All/Thin/Cmp Copies IO Group 0 1001 1 GB 1001/0/0 IO Group 1 0 0 GB 0/0/0 IO Group 2 0 0 GB 0/0/0 IO Group 3 0 0 GB 0/0/0 IO Group 4 0 0 GB 0/0/0 Type Virtual Capacity Real Capacity Used Capacity Uncompressed Used Capacity Thin 0 GB 0 GB 0 GB 0 GB Compressed 0 GB 0 GB 0 GB 0 GB # End # FlashCopy_Information: Number of FC Maps defined on the Cluster: 0 Number of FC Consistency Groups defined on the Cluster: 0 Number of Incremental FC Maps defined on the Cluster: 0 # End # RemoteCopy_Information: Topology: standard Partners: 0 FC Partners: 0 IPV4 Partners: 0 IPV6 Partners: 0 Number of RC Relationships defined on the Cluster: 0 Number of RC Consistency Groups defined on the Cluster: 0 # End # Node_Hardware: id 1 name node1 status online IO_group_id 0 IO_group_name io_grp0 hardware 500 actual_different yes actual_valid no memory_configured 32 memory_actual 32 memory_valid yes cpu_count 1 cpu_socket 1 cpu_configured 8 core Intel Xeon cpu_actual 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_valid yes adapter_count 6 adapter_location 0 adapter_configured 12Gb/s SAS adapter adapter_actual 12Gb/s SAS adapter adapter_valid yes adapter_location 0 adapter_configured Midplane bus adapter adapter_actual Midplane bus adapter adapter_valid yes adapter_location 0 adapter_configured Four port 1Gb/s Ethernet adapter adapter_actual Four port 1Gb/s Ethernet adapter adapter_valid yes adapter_location 1 adapter_configured Compression pass-through adapter_actual Compression pass-through adapter_valid yes adapter_location 2 adapter_configured Four port 8Gb/s FC adapter adapter_actual Four port 8Gb/s FC adapter adapter_valid yes adapter_location 3 adapter_configured none adapter_actual unknown adapter_valid no ports_different no # End # Node_Hardware: id 2 name node2 status online IO_group_id 0 IO_group_name io_grp0 hardware 500 actual_different no actual_valid yes memory_configured 32 memory_actual 32 memory_valid yes cpu_count 1 cpu_socket 1 cpu_configured 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_actual 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_valid yes adapter_count 6 adapter_location 0 adapter_configured 12Gb/s SAS adapter adapter_actual 12Gb/s SAS adapter adapter_valid yes adapter_location 0 adapter_configured Midplane bus adapter adapter_actual Midplane bus adapter adapter_valid yes adapter_location 0 adapter_configured Four port 1Gb/s Ethernet adapter adapter_actual Four port 1Gb/s Ethernet adapter adapter_valid yes adapter_location 1 adapter_configured Compression pass-through adapter_actual Compression pass-through adapter_valid yes adapter_location 2 adapter_configured Four port 8Gb/s FC adapter adapter_actual Four port 8Gb/s FC adapter adapter_valid yes adapter_location 3 adapter_configured none adapter_actual none adapter_valid yes ports_different no # End # Key_Based_Licensing_Information: id:name:state:trial_expiration_date 0:encryption:active: # End # VVol_metadatavdisk_Information: # End # LSSRA_srastatus_Information: status:disabled active_monitor_user_count:0 monitor_user_last_login: active_privileged_user_count:0 privileged_user_last_login: token_age_in_days:0 remote_support_test_status:disconnected remote_support_test_time: remote_support_config_changed_after_test:no remote_support_enabled:no remote_support_status:disconnected remote_support_enabled_time: remote_support_idletimeout:0 remote_support_center_id: # End # Cloud_Account_Information: # End # Cloud_Snapshot_Information: Number of volumes with cloud snapshots: 0 # End # JSON: eNrs3VlzY0l2rum/EpbXqjzw2V1XXcORrC6qVHaqZbqQyWgIEhHJU5wEkhkKlem/NwYO7sBCYIHfjpWR 0Z/auruSRIBrb38d0wOCf/9hubi/fVyeL84uL374x3c/zNb/52azkPNs5mf+h39498PPi+X95e3N+tvu x9n6K8vFfz4u7h/OHi6vF+sv+5mrv5mF38z8O+f/cdb+0ed3//r//n590Yv5w3x1kb//cHX/8+3V4/Xi /fz8b493d8vbj6sffb/+1v/8w+qbi58XNw8/Xd4/3C4/r77473//YfOV57Fims3S+vqeLvL0dbf+0vaC D5/vNrMs55f3i4v11+/XU96sDu3m8fr9Yrm5/Cz88D//8G7nyourcbZ/5f7kK8/Cldc6257G8crDyVfe hCtfnRbf9q88nnrlLkmTxzBz+1eeTr7y1Wn5j/UaLxd388vlzxeX9387v737vNfA5jv3n2/O976z+sb5 . . (many similar lines were removed from this example) . 2k6eOumfmAyLxU//YwHwX998880Cfrb48a9+/fOnLE9n1x0lyRPf+3ZK06v7G8KJlj758QJ22/nD3dXm 7uJIg51Zsd9ttvNg+u27HZM/rBkcU9j+1T//+rO2aKKLz76Cvnj27K0n6XfLm5PZOx7NPfBuDOdXD9L6 ODw6evFwR3t0JN5PRPM5/h/484MB//eeuS155urLcfp3mbm//Kr6zG1u5rZ/pJnbszOXh/w9Zu6nwMVn bhM3c/s/0swd2TOXTuHvMnOH/u1mbvthhu7CTd3xjzR1Ift2Yal/nxtdHX+7qbv4YU7d7qYu/CNNXcxO Xeh/nzvdb/7rbzd1+w9z6oKbupg7dT9w5rb94+GPn7z0AZP3sGrzgbcMqydudj942j4uFr/P3cIv33Pe Pm71yW/+T77TVTdx5/P2Y6btOH571dXV7f1K2Z//8pe//H8YHHro # End