In order to restart a Lenovo Storage V7000 Gen2 enclosure,
you might have to reseat a node canister.
- If enclosure input power was removed from both power supply units,
the input power LED of both PSUs is off. To restart the enclosure,
complete the following steps:
- Ensure that both node canisters and PSUs are installed correctly.
- Reconnect the input power to the enclosure PSUs.
Each canister power LED fast-blinks for a few seconds before
turning on. The node canister is online when its Status LED is on.
- If either power supply unit of a control enclosure has output
LEDs on, then the enclosure is already powered. In this enclosure,
a node canister that has a slow blinking Power LED can be restarted
by reseating the canister. After reseating, the canister power LED
fast-blinks for a few seconds before turning on. The node canister
is online when its Status LED is on.