If you have a Sun host and existing SAN boot images that
are controlled by storage controllers, you can migrate these images
to image-mode volumes that are controlled by the Lenovo Storage V7000 system.
To migrate your existing SAN boot images, complete the following
steps:
- Shut down the host.
- Complete the following configuration changes on the storage
controller:
- Remove all the image-to-host mappings from the storage
controller.
- Map the existing SAN boot image and any other disks
that you want to present to the system.
- Zone one port of each host bus adapter
(HBA) to one of the system ports that is associated with the I/O group
for the target image-mode volume.
- Complete the following configuration changes on the system:
- Create an image-mode volume for the managed
disk (MDisk) that contains the SAN boot image.
Use the MDisk unique identifier to specify the correct MDisk.
- Create a host object and assign it to
the HBA port that you zoned to system port in step 3.
- Map the image mode volume to the host.
For example, you might map the swap disk to the host with SCSI
LUN ID 0.
- Map the swap disk to the host, if necesary.
For example, you might map the swap disk to the host with SCSI
LUN ID 1.
- Restart the host.