An inventory information email summarizes the hardware components and configuration of a system. Service personnel can use this information to contact you when relevant software updates are available or when an issue that can affect your configuration is discovered. It is a good practice to enable inventory reporting.
Because inventory information is sent using the Call Home email function, you must meet the Call Home function requirements and enable the Call Home email function before you can attempt to send inventory information email. You can adjust the contact information, adjust the frequency of inventory email, or manually send an inventory email using the management GUI or the command-line interface.
# Timestamp = Thu May 21 12:01:06 2015 # Timezone = +0100, BST # Organization = IBM UK # Machine Address = Maybrook Hall # Machine City = Manchester # Machine State = XX # Machine Zip = M3 2EG # Machine Country = GB # Contact Name = Mike Programmer # Alternate Contact Name = N/A # Contact Phone Number = 000000000 # Alternate Contact Phone Number = N/A # Offshift Phone Number = N/A # Alternate Offshift Phone Number = N/A # Contact Email = m.programmer@system.com # Machine Location = JSH # Machine Type = 2076524 # Serial Number = 03CK00C # Machine Part Number = # System Version = 7.5.0.0 (build 115.48.1505142248000) # Record Type = 6 # Frequency = 7 # Cluster_VPD: id:0000010022DFFE26 name:mcr-fab1-cluster-13 location:local partnership: bandwidth: total_mdisk_capacity:5.4TB space_in_mdisk_grps:5.4TB space_allocated_to_vdisks:280.53GB total_free_space:5.2TB statistics_status:on statistics_frequency:15 required_memory:32768 cluster_locale:en_US time_zone:375 Europe/London code_level:7.5.0.0 (build 115.48.1505142248000) FC_port_speed:2Gb id_alias:0000010022BFFE26 gm_link_tolerance:300 gm_inter_cluster_delay_simulation:0 gm_intra_cluster_delay_simulation:0 email_reply:m.programmer@system.com email_contact:Mike Programmmer email_contact_primary:000000000 email_contact_alternate: email_contact_location:JSH email_state:running inventory_mail_interval:7 total_vdiskcopy_capacity:300.00GB total_used_capacity:52.04GB total_overallocation:5 total_vdisk_capacity:300.00GB iscsi_auth_method:none auth_service_configured:no auth_service_enabled:no auth_service_pwd_set:no auth_service_cert_set:no relationship_bandwidth_limit:25 gm_max_host_delay:5 tier:ssd tier_capacity:0.00MB tier_free_capacity:0.00MB tier:enterprise tier_capacity:5.44TB tier_free_capacity:5.16TB tier:nearline tier_capacity:0.00MB tier_free_capacity:0.00MB email_contact2: email_contact2_primary: email_contact2_alternate: total_allocated_extent_capacity:289.00GB has_nas_key:no auth_service_type:tip layer:replication rc_buffer_size:48 cache_prefetch:on email_organization:IBM UK email_machine_address:Maybrook Hall email_machine_city:Manchester email_machine_state:XX email_machine_zip:M3 2EG email_machine_country:GB high_temp_mode:off # End # Cluster_Size: Number of Nodes in Cluster: 2 # Node_VPD: id 1 system board: 24 fields part_number 00RY381 system_serial_number 11S31P1844YM10BG3C9001 number_of_processors 1 number_of_memory_modules 2 number_of_fans 0 number_of_generic_devices 1 number_of_FC_adapters 1 number_of_Ethernet_adapters 1 number_of_SAS_adapters 1 number_of_Bus_adapters 1 number_of_IB_adapters 0 number_of_power_supplies 0 number_of_local_managed_disks 0 BIOS_manufacturer American Megatrends Inc. BIOS_version FABFD010 BIOS_release_date 09/17/2014 system_manufacturer IBM system_product FAB1 Controller planar_manufacturer IBM CMOS_battery_part_number 33F8354 frame_assembly_part_number N/A power_cable_assembly_part_number N/A service_processor_firmware disk_controller 00RY381 processor: 6 fields part_number 00RY381 processor_location 1 manufacturer Intel version Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz speed 1901 status Enabled memory module: 24 fields part_number 64P8453 device_location Node0_Dimm0 bank_location Node0_Bank0 size (MB) 16384 manufacturer Micron serial_number 43333A16 part_number 64P8453 device_location Node0_Dimm1 bank_location Node0_Bank0 size (MB) N/A manufacturer Dimm1_Manufacturer serial_number Dimm1_SerNum part_number 64P8453 device_location Node0_Dimm2 bank_location Node0_Bank0 size (MB) 16384 manufacturer Micron serial_number 43333A87 part_number 64P8453 device_location Node0_Dimm3 bank_location Node0_Bank0 size (MB) N/A manufacturer Dimm3_Manufacturer serial_number Dimm3_SerNum Adapter card: 27 fields card_type SAS part_number 00RY381 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Unknown device SPCve 16x12G SAS card_revision Unknown chip_revision 1.1 card_type Bus part_number 00RY381 port_numbers 1 location 0 device_serial_number Unknown manufacturer Unknown device PCIe Gen3 Switch card_revision Unknown chip_revision 50.2 card_type Ethernet part_number 00RY381 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Unknown device I350 Ethernet card_revision Unknown chip_revision 0.1 Ethernet port: 33 fields part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 1 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 2 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 3 Adapter card: 18 fields card_type Compression part_number 31P1861 port_numbers 1 location 1 device_serial_number Unknown manufacturer Unknown device Compression card_revision Unknown chip_revision Unknown card_type FC part_number 64P8473 port_numbers 1 2 3 4 location 2 device_serial_number 11S64P8475YM10MY42D244 manufacturer IBM device QE8 8G FC card_revision 3 chip_revision 2.0 Fibre channel port: 44 fields part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL09M supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 1 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL09R supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 2 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL09L supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 3 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL09U supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 4 device: 8 fields part_number 00RY381 bus sata device 0 model SanDisk SD6SA1M128G1011 revision X230600 serial_number SD6SA1M140804400299 approx_capacity 119 hw_revision system code level: 4 fields id 1 node_name node1 WWNN 0x500507680b00fe26 code_level 7.5.0.0 (build 115.48.1505142248000) front panel assembly: 3 fields part_number N/A front_panel_id 01-1 dump_name 03CK00C-1 # End # Node_VPD: id 2 system board: 24 fields part_number 00RY381 system_serial_number 11S31P1844YM10BG3C900L number_of_processors 1 number_of_memory_modules 2 number_of_fans 0 number_of_generic_devices 1 number_of_FC_adapters 1 number_of_Ethernet_adapters 1 number_of_SAS_adapters 1 number_of_Bus_adapters 1 number_of_IB_adapters 0 number_of_power_supplies 0 number_of_local_managed_disks 0 BIOS_manufacturer American Megatrends Inc. BIOS_version FABFD010 BIOS_release_date 09/17/2014 system_manufacturer IBM system_product FAB1 Controller planar_manufacturer IBM CMOS_battery_part_number 33F8354 frame_assembly_part_number N/A power_cable_assembly_part_number N/A service_processor_firmware disk_controller 00RY381 processor: 6 fields part_number 00RY381 processor_location 1 manufacturer Intel version Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz speed 1901 status Enabled memory module: 24 fields part_number 64P8453 device_location Node0_Dimm0 bank_location Node0_Bank0 size (MB) 16384 manufacturer Micron serial_number 433339F5 part_number 64P8453 device_location Node0_Dimm1 bank_location Node0_Bank0 size (MB) N/A manufacturer Dimm1_Manufacturer serial_number Dimm1_SerNum part_number 64P8453 device_location Node0_Dimm2 bank_location Node0_Bank0 size (MB) 16384 manufacturer Micron serial_number 433339F3 part_number 64P8453 device_location Node0_Dimm3 bank_location Node0_Bank0 size (MB) N/A manufacturer Dimm3_Manufacturer serial_number Dimm3_SerNum Adapter card: 27 fields card_type SAS part_number 00RY381 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Unknown device SPCve 16x12G SAS card_revision Unknown chip_revision 1.1 card_type Bus part_number 00RY381 port_numbers 1 location 0 device_serial_number Unknown manufacturer Unknown device PCIe Gen3 Switch card_revision Unknown chip_revision 50.2 card_type Ethernet part_number 00RY381 port_numbers 1 2 3 location 0 device_serial_number Unknown manufacturer Unknown device I350 Ethernet card_revision Unknown chip_revision 0.1 Ethernet port: 33 fields part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 1 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 2 part_number Unknown manufacturer N/A device N/A serial_number N/A supported_speeds 10,100 Mbps,1 Gbps connector_type N/A transmitter_type N/A wavelength N/A max_distance_by_cable_type N/A hw_revision N/A port_number 3 Adapter card: 18 fields card_type Compression part_number 31P1861 port_numbers 1 location 1 device_serial_number Unknown manufacturer Unknown device Compression card_revision Unknown chip_revision Unknown card_type FC part_number 64P8473 port_numbers 1 2 3 4 location 2 device_serial_number 11S64P8475YM10MY42D212 manufacturer IBM device QE8 8G FC card_revision 3 chip_revision 2.0 Fibre channel port: 44 fields part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL0A7 supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 1 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL09P supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 2 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL083 supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 3 part_number 85Y6278 manufacturer JDSU device PLRXPLVCSH4B1N serial_number CE06EL0A9 supported_speeds 2,4,8 Gbps connector_type LC transmitter_type SN wavelength 850 max_distance_by_cable_type OM1:20,OM2:50,OM3:150 hw_revision 2 port_number 4 device: 8 fields part_number 00RY381 bus sata device 0 model SanDisk SD6SA1M128G1011 revision X230600 serial_number SD6SA1M140804400305 approx_capacity 119 hw_revision system code level: 4 fields id 2 node_name node2 WWNN 0x500507680b00fe27 code_level 7.5.0.0 (build 115.48.1505142248000) front panel assembly: 3 fields part_number N/A front_panel_id 01-2 dump_name 03CK00C-2 # End # License_Information: used_flash 0.00 used_remote 0.00 used_virtualization 0.00 license_flash 0 license_remote 10 license_virtualization 10 license_physical_disks 0 license_physical_flash off license_physical_remote off used_compression_capacity 0.00 license_compression_capacity 0 license_compression_enclosures 10 license_easy_tier 0 # End # Controller_Information: Number of Controllers in Cluster: 0 # End # Host_Information: Number of Hosts connected to the Cluster: 2 Host Details: Host Id FC Ports iSCSI Ports SAS Ports 0 2 0 0 1 2 0 0 # End # Enclosure_Information: Number of Enclosures in the Cluster: 1 Enclosure Details: Model Type Serial Number FRU Part Number FRU Identity 2076-524 03CK00C 31P1854 11S31P1841YM10BG3CK00C # End # RAID_Information: Number of RAID Arrays in the Cluster: 3 RAID Details: Raid Level Number of Disks Capacity in TB Raid0 0 0 Raid1 0 0 Raid5 3 5 Raid6 0 0 Raid10 0 0 # End # Drive_Information: Number of Drives in the Cluster: 24 Drive Details: Use Product Id FRU PN FRU Identity FW Level member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV70UPF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6YEEF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLGSTRJF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6X13F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV8BG7F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV70Z7F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6X95F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLGSTZXF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV105LF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6YS3F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLGST4NF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV70K7F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV0Y0ZF J2E6 spare HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6XLUF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV0Y5YF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLGSW6ZF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6XJ6F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6YKEF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV0ZGLF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV646JF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV6Y7PF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV2161F J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV0Z8LF J2E6 member HUC109030CSS60 00Y2682 11S49Y7446YXXXKLV8BNWF J2E6 # End # MDisk_Information: Number of MDisks in the Cluster: 3 MDisk Details: Mode Number of MDisks Max Size Internal 3 1952 GB External 0 0 GB # End # Easy_Tier_Information: Number of MDiskGrps in the Cluster: 1 Easy Tier Details: MDiskGrp Id SSD Disks SSD Capacity Enterprise Disks Enterprise Capacity Nearline Disks Nearline Capacity 0 0 0.00MB 3 5.44TB 0 0.00MB Number of Easy Tier MDiskGrps in the Cluster: 1 # End # VDisk_Information: Number of VDisks in the Cluster: 9 VDisk Details: IO Group Number of VDisks Max Size All/Thin/Cmp Copies IO Group 0 9 50 GB 9/9/0 IO Group 1 0 0 GB 0/0/0 IO Group 2 0 0 GB 0/0/0 IO Group 3 0 0 GB 0/0/0 IO Group 4 0 0 GB 0/0/0 Type Virtual Capacity Real Capacity Used Capacity Uncompressed Used Capacity Thin 300 GB 280 GB 52 GB 52 GB Compressed 0 GB 0 GB 0 GB 0 GB # End # FlashCopy_Information: Number of FC Maps defined on the Cluster: 0 Number of FC Consistency Groups defined on the Cluster: 1 Number of Incremental FC Maps defined on the Cluster: 0 # End # RemoteCopy_Information: Number of RC Relationships defined on the Cluster: 0 Number of RC Consistency Groups defined on the Cluster: 0 # End # Node_Hardware: id 1 name node1 status online IO_group_id 0 IO_group_name io_grp0 hardware 500 actual_different no actual_valid yes memory_configured 32 memory_actual 32 memory_valid yes cpu_count 1 cpu_socket 1 cpu_configured 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_actual 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_valid yes adapter_count 6 adapter_location 0 adapter_configured 12Gb/s SAS adapter adapter_actual 12Gb/s SAS adapter adapter_valid yes adapter_location 0 adapter_configured Midplane bus adapter adapter_actual Midplane bus adapter adapter_valid yes adapter_location 0 adapter_configured Four port 1Gb/s Ethernet adapter adapter_actual Four port 1Gb/s Ethernet adapter adapter_valid yes adapter_location 1 adapter_configured Compression pass-through adapter_actual Compression pass-through adapter_valid yes adapter_location 2 adapter_configured Four port 8Gb/s FC adapter adapter_actual Four port 8Gb/s FC adapter adapter_valid yes adapter_location 3 adapter_configured none adapter_actual none adapter_valid yes ports_different no # End # Node_Hardware: id 2 name node2 status online IO_group_id 0 IO_group_name io_grp0 hardware 500 actual_different no actual_valid yes memory_configured 32 memory_actual 32 memory_valid yes cpu_count 1 cpu_socket 1 cpu_configured 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_actual 8 core Intel(R) Xeon(R) CPU E5-2628L v2 @ 1.90GHz cpu_valid yes adapter_count 6 adapter_location 0 adapter_configured 12Gb/s SAS adapter adapter_actual 12Gb/s SAS adapter adapter_valid yes adapter_location 0 adapter_configured Midplane bus adapter adapter_actual Midplane bus adapter adapter_valid yes adapter_location 0 adapter_configured Four port 1Gb/s Ethernet adapter adapter_actual Four port 1Gb/s Ethernet adapter adapter_valid yes adapter_location 1 adapter_configured Compression pass-through adapter_actual Compression pass-through adapter_valid yes adapter_location 2 adapter_configured Four port 8Gb/s FC adapter adapter_actual Four port 8Gb/s FC adapter adapter_valid yes adapter_location 3 adapter_configured none adapter_actual none adapter_valid yes ports_different no # End # Key_Based_Licensing_Information: id:name:state:trial_expiration_date 0:encryption:inactive: # End # VVol_metadatavdisk_Information: # End