The GUI access enables the intuitive setup of the NetApp E-Seriesstorage system logical
unit numbers (LUNs) and masking/export to the Lenovo Storage V7000 system.
The setup is straightforward as Lenovo Storage V7000 detects
the controller without a LUN being presented. Mask LUNs exclusively
to Lenovo Storage V7000 as
a host group.
You must configure the following settings for
NetApp E-Series systems:
- Set the host type for Lenovo Storage V7000 to SVC.
- Set the system so that both storage systems have
the same worldwide node name (WWNN).
- Ensure that the AVT option is enabled. The host type selection SVC enables
the AVT option. View the storage system profile data to confirm that
you have the AVT option enabled.
- You must have the following options that are enabled on any logical
units that are mapped to NetApp E-Seriessystems:
- Read caching
- Write caching
- Write cache mirroring
- You must not have caching without batteries enabled.