Use the lsdrive command to display configuration information and drive vital product data (VPD).
Attribute | Value |
---|---|
id | Indicates the ID of the drive:
|
status | Indicates the summary status of the drive. |
error_sequence_number | Indicates the error sequence number describing
the cause of the drive status:
Note: Error sequence numbers indicate an entry in the event log.
This includes entries that are both errors, and informational messages
(for example, the drive is formatting).
|
use | Indicates the current role of the drive:
|
UID | Indicates the unique ID reported by the drive. |
tech_type | Indicates the drive technology used. |
capacity | Indicates the capacity of disk, excluding quorum area. |
block_size | Indicates the block size of the disk. |
vendor_id | Indicates the manufacturer of the drive. |
product_id | Indicates the product ID of the drive. |
FRU_part_number | Indicates the FRU part number of the drive. |
FRU_identity | Indicates the 11S number combining manufacturing part number and serial number. |
RPM | Indicates the specified RPM of the disk. |
firmware_level | Indicates the firmware level of the disk; blank if unknown. |
FPGA_level | Indicates the FPGA level, if applicable; blank if not applicable or unknown. |
mdisk_id | Indicates the ID of the array MDisk that the drive is a member of. |
mdisk_name | Indicates the name of the MDisk that the drive is a member of. |
member_id | Indicates the ID of the MDisk array member. |
enclosure_id | Indicates if the:
|
slot_id | Indicates the slot_id of the drive in the enclosure or node. It can be referred to as the drive bay or location. This can be blank. |
node_name | Indicates the node name where the drive is located for a drive contained within a node. For a drive contained within an enclosure, it is blank. |
node_id | Indicates the node ID where the drive is located for a drive contained within a node. For a drive contained within an enclosure, blank. |
quorum_id | Indicates the ID of quorum disk; blank if not quorum disk. |
port_1_status | Indicates the connectivity status of the drive's
first port. The values are online, offline, or excluded. Note: Port 1 is attached to the node
that has a panel name ending in -1.
|
port_2_status | Indicates the connectivity status
of the drive's second port. The values are online, offline, or excluded. Note: Port
2 is attached to the node that has a panel name ending in -2.
|
interface_speed | Indicates the lowest interface speed for the
connected drive slot (in gigabits per second, or Gbps). The values
are:
|
protection_enabled | Indicates if SCSI type-2 protection information is enabled (yes) or not (no). |
auto_manage | Indicates if the auto_manage process is running (active) or not running (idle). |
drive_class_id | Indicates which drive class the drive is part of. |
lsdrive -delim :
The concise resulting output:
id:status:error_sequence_number:use:tech_type:capacity:mdisk_id:mdisk_name:member_id:enclosure_id:slot_id:auto_manage:drive_class_id 0:online::member:sas_ssd:20GB:0:mdisk0:0:1:2:active:0 1:offline:345:member:sas_ssd:20GB:0:mdisk0:0:1:3:idle:0 2:online::member:sas_ssd:20GB:0:mdisk0:0:1:4:active:0
lsdrive 0
The detailed resulting output:
id:0 status:online error_sequence_number: use:member UID:20000004cf4cd2c0 tech_type:ssd capacity:20GB block_size:512 vendor_id:IBM product_id:I8MR1337 W00Y4Y1 FRU_part_number:AAAAAAA FRU_identity:11S1817115Y41337171001 RPM:15000 firmware_level:3.02 FPGA_level:1.99 mdisk_id:0 mdisk_name:mdisk0 member_id:0 enclosure_id:1 slot:2 node_id: node_name: quorum_id: port_1_status:online port_2_status:online interface_speed:6Gbprotection_enabled:yesauto_manage:activedrive_class_id:3