Controller settings apply across one HSG80 controller.
Table 1 describes the options that can be set by HSG80 controller command-line interface (CLI) commands for each HSG80 controller.
Option | HSG80 controller default setting | Lenovo Storage V7000 required setting |
---|---|---|
ALLOCATION_CLASS | 0 | Any value |
CACHE_FLUSH_TIME | 10 | Any value |
COMMMAND_CONSOLE_LUN | Not defined | Any value |
CONNECTIONS_UNLOCKED | CONNECTIONS_ |
CONNECTIONS_ |
NOIDENTIFIER | Not defined | No identifier |
MIRRORED_CACHE | Not defined | Mirrored |
MULTIBUS_FAILOVER | Not defined | MULTIBUS_FAILOVER |
NODE_ID | Worldwide name as on the label | Default |
PROMPT | None | Any value |
REMOTE_COPY | Not defined | Any value |
SCSI_VERSION | SCSI-2 | SCSI-3 |
SMART_ERROR_EJECT | Disabled | Any value |
TERMINAL_PARITY | None | Any value |
TERMINAL_SPEED | 9600 | Any value |
TIME | Not defined | Any value |
UPS | Not defined | Any value |