You must configure the operating system before you can use Tru64 UNIX on HP AlphaServer hosts with the Lenovo Storage V7000 system.
The following example shows output from the hwmgr view devices command:
# hwmgr sh s SCSI DEVICE DEVICE DRIVER NUM DEVICE FIRST HWID: DEVICEID HOSTNAME TYPE SUBTYPE OWNER PATH FILE VALID PATH ------------------------------------------------------------------------- 104: 0 es47 disk none 2 1 dsk0 [1/0/0] 105: 1 es47 disk none 0 1 dsk1 [1/1/0] 106: 2 es47 cdrom none 0 1 cdrom0 [2/0/0] 246: 77 es47 disk none 2 8 dsk76 [0/6/0] 247: 78 es47 disk none 2 8 dsk77 [4/2/1] 248: 79 es47 disk none 2 8 dsk78 [0/6/2] 249: 80 es47 disk none 0 8 dsk79 [4/7/3] 250: 3 es47 disk none 0 8 dsk80 [4/7/4] # hwmgr show scsi -full -id 250 SCSI DEVICE DEVICE DRIVER NUM DEVICE FIRST HWID: DEVICEID HOSTNAME TYPE SUBTYPE OWNER PATH FILE VALID PATH ------------------------------------------------------------------------- 250: 3 es47 disk none 0 4 dsk80 [4/7/4] WWID:01000010:6005-0768-0193-8100-5000-0000-0000-0014 BUS TARGET LUN PATH STATE --------------------------------- 4 7 4 valid 3 5 4 valid 0 5 4 valid 4 2 4 valid #