Configuration requirements for Tru64 UNIX on HP AlphaServer hosts

You must configure the operating system before you can use Tru64 UNIX on HP AlphaServer hosts with the Lenovo Storage V7000 system.

Before you configure the host operating system, the following tasks must be completed:
After the prerequisite tasks are complete, use the following general steps to configure your Tru64 UNIX host system.
  1. Zone the host system to the Lenovo Storage V7000 system on the Fibre Channel SAN.
  2. Configure and map volumes to the host.
  3. For Tru64 UNIX 5.1 and later versions, you can discover the disks by using the hwmgr scan scsi command.

    The disks are discovered as Lenovo2145 disks, and the number of discovered devices depends on the number of adapters and zoned paths to the Lenovo Storage V7000 system.

  4. Optionally, check the status and number of attached disks by using the following commands:
    • hwmgr view devices
    • hwmgr show scsi
    • hwmgr show components

The following example shows output from the hwmgr view devices command:

The following example shows output from the hwmgr show scsi command:
# hwmgr sh s

        SCSI                DEVICE    DEVICE  DRIVER NUM  DEVICE FIRST
 HWID:  DEVICEID HOSTNAME   TYPE      SUBTYPE OWNER  PATH FILE   VALID PATH
-------------------------------------------------------------------------
  104:  0        es47       disk      none    2      1    dsk0   [1/0/0]
  105:  1        es47       disk      none    0      1    dsk1   [1/1/0]
  106:  2        es47       cdrom     none    0      1    cdrom0 [2/0/0]
  246:  77       es47       disk      none    2      8    dsk76  [0/6/0]
  247:  78       es47       disk      none    2      8    dsk77  [4/2/1]
  248:  79       es47       disk      none    2      8    dsk78  [0/6/2]
  249:  80       es47       disk      none    0      8    dsk79  [4/7/3]
  250:  3        es47       disk      none    0      8    dsk80  [4/7/4]
# hwmgr show scsi -full -id 250

        SCSI                DEVICE    DEVICE  DRIVER NUM  DEVICE FIRST
 HWID:  DEVICEID HOSTNAME   TYPE      SUBTYPE OWNER  PATH FILE   VALID PATH
-------------------------------------------------------------------------
  250:  3        es47       disk      none    0      4    dsk80  [4/7/4]

      WWID:01000010:6005-0768-0193-8100-5000-0000-0000-0014

      BUS   TARGET  LUN   PATH STATE
      ---------------------------------
      4     7       4     valid
      3     5       4     valid
      0     5       4     valid
      4     2       4     valid
#