For IBM® FlashSystem™, logical units are enumerated devices that have the same characteristics as LUNs.
The IBM FlashSystem system has a maximum LUN size of 40 TB.
The IBM FlashSystem system can export 512 LUNs to the Lenovo Storage V7000 system, which is the Lenovo Storage V7000 limit. Lenovo Storage V7000 supports greater than 2 TB LUNs.
The IBM FlashSystem system identifies exported logical units through SCSI identification descriptor type 3. The 64-bit NAA IEEE Registered Extended Identifier (NAA=6) for the logical unit is in the form 6-OUI-VSID. For example, the model 9840-AE1 IEEE company ID is 005076 (IBM). The remaining part of the company ID is a vendor-specific ID.
# lsmdisk 121 id 121 name mdisk121 status online mode managed mdisk_grp_id 8 mdisk_grp_name texan2 capacity 50.0GB quorum_index block_size 512 controller_name texan2 ctrl_type 4 ctrl_WWNN 500507605EBFECC0 controller_id 19 path_count 32 max_path_count 32 ctrl_LUN_# 000000000000000D UID 6005076001810000000000001900001b00000000000000000000000000000000 preferred_WWPN active_WWPN many fast_write_state empty raid_status raid_level redundancy strip_size spare_goal spare_protection_min balanced tier generic_hdd slow_write_priority fabric_type fc site_id site_name #
svctask mkarray -level raid0/5
A storage pool is provisioned automatically from which the volumes can be provisioned and presented to Lenovo Storage V7000.
Generally, it is best to provide a few large LUNs to Lenovo Storage V7000 (4 or 8) from the available capacity.
http://www.redbooks.ibm.com/redbooks.nsf/redbookabstracts/tips1079.html?Open&c4#contents
svctask chsystem -openaccess off
There are no special considerations for logical unit numbering. LUN 0 can be exported where necessary.
A IBM FlashSystemstorage system can have a total of 16 8 GB Fibre Channel ports.
# lscontroller id controller_name ctrl_s/n vendor_id product_id_low product_id_high 19 texan2 000060400000-0000-0 IBM FlashSys tem-9840
# lscontroller 19 id 19 controller_name texan2 WWNN 500507605EBFECC0 mdisk_link_count 15 max_mdisk_link_count 512 degraded no vendor_id IBM product_id_low FlashSys product_id_high tem-9840 product_revision 1103 ctrl_s/n 000060400000-0000-0 allow_quorum yes fabric_type fc site_id site_name WWPN 500507605EBFECE4 path_count 120 max_path_count 4096 WWPN 500507605EBFECC4 path_count 120 max_path_count 4096 WWPN 500507605EBFECD4 path_count 120 max_path_count 4096 WWPN 500507605EBFECF4 path_count 120 max_path_count 409 #
5005076SSSSSSSPP 5 - IEEE 803.2 ID NAA format, 005076 - IEEE unique VSID for IBM. (common with SVC) SSSSSS - unique vendor-supplied serial number for the device. PP - vendor specific code used to identify specific ports WWNN 500507605EBFF2C0 WWPN 500507605EBFF2E1 WWPN 500507605EBFF2D1 WWPN 500507605EBFF2C1 WWPN 500507605EBFF2F1
All systems are Active/Active. To avoid an outage from system failure, cross connect the ports across Fibre Channel switches. Because all IBM FlashSystemstorage systems are equal in priority, there is no benefit to using an exclusive set for a specific LU.
There are no preferred access ports on the IBM FlashSystem system as all ports are Active/Active across all systems.
Detecting ownership does not apply to IBM FlashSystem storage arrays.