The informational events provide information about the status of an operation.
Informational events are recorded in the event log and, based on notification type, can be notified through email, SNMP, or syslog.
Informational events can be either notification type I (information) or notification type W (warning). An informational event report of type (W) might require user attention. Table 1 provides a list of informational events, the notification type, and the reason for the event.
Event ID | Notification type | Description |
---|---|---|
980221 | I | The error log is cleared. |
980230 | I | The SSH key was discarded for the service login user. |
980231 | I | User name has changed. |
980301 | I | Degraded or offline managed disk is now online. |
980310 | I | A degraded or offline storage pool is now online. |
980320 | I | Offline volume is now online. |
980321 | W | Volume is offline because of degraded or offline storage pool. |
980330 | I | All nodes can see the port. |
980349 | I | A node has been successfully added to the cluster (system). |
980350 | I | The node is now a functional member of the cluster (system). |
980351 | I | A noncritical hardware error occurred. |
980352 | I | Attempt to automatically recover offline node starting. |
980370 | I | Both nodes in the I/O group are available. |
980371 | I | One node in the I/O group is unavailable. |
980372 | W | Both nodes in the I/O group are unavailable. |
980380 | I | Maintenance mode was started. |
980381 | I | Maintenance mode has ended. |
980392 | I | Cluster (system) recovery completed. |
980435 | W | Failed to obtain directory listing from remote node. |
980440 | W | Failed to transfer file from remote node. |
980445 | I | The migration is complete. |
980446 | I | The secure delete is complete. |
980501 | W | The virtualization amount is close to the limit that is licensed. |
980502 | W | The FlashCopy feature is close to the limit that is licensed. |
980503 | W | The Metro Mirror or Global Mirror feature is close to the limit that is licensed. |
980504 | I | The limit was reached for the external virtualization feature. |
980505 | I | The limit was reached for the compression feature license. |
981002 | I | Fibre Channel discovery occurred; configuration changes are pending. |
981003 | I | Fibre Channel discovery occurred; configuration changes are complete. |
981004 | I | Fibre Channel discovery occurred; no configuration changes were detected. |
981007 | W | The managed disk is not on the preferred path. |
981009 | W | The initialization for the managed disk failed. |
981014 | W | The LUN discovery has failed. The cluster (system) has a connection to a device through this node but this node cannot discover the unmanaged or managed disk that is associated with this LUN. |
981015 | W | The LUN capacity equals or exceeds the maximum. Only part of the disk can be accessed. |
981020 | W | The managed disk error count warning threshold has been met. |
981022 | I | Managed disk offline imminent, offline prevention started |
981025 | I | Drive firmware download completed successfully |
981026 | I | Drive FPGA download completed successfully |
981027 | I | Drive firmware download started |
981028 | I | Drive FPGA download started |
981029 | I | Drive firmware download cancelled by user |
981101 | I | SAS discovery occurred; no configuration changes were detected. |
981102 | I | SAS discovery occurred; configuration changes are pending. |
981103 | I | SAS discovery occurred; configuration changes are complete. |
981104 | W | The LUN capacity equals or exceeds the maximum capacity. Only the first 1 PB of disk will be accessed. |
981105 | I | The drive format has started. |
981106 | I | The drive recovery was started. |
982003 | W | Insufficient virtual extents. |
982004 | W | The migration suspended because of insufficient virtual extents or too many media errors on the source managed disk. |
982007 | W | Migration has stopped. |
982009 | I | Migration is complete. |
982010 | W | Copied disk I/O medium error. |
983001 | I | The FlashCopy operation is prepared. |
983002 | I | The FlashCopy operation is complete. |
983003 | W | The FlashCopy operation has stopped. |
984001 | W | First customer data being pinned in a volume working set. |
984002 | I | All customer data in a volume working set is now unpinned. |
984003 | W | The volume working set cache mode is in the process of changing to synchronous destage because the volume working set has too much pinned data. |
984004 | I | Volume working set cache mode updated to allow asynchronous destage because enough customer data has been unpinned for the volume working set. |
984005 | W | Volumes have been taken offline because the storage pool's cache is full of data that cannot be destaged. |
984006 | W | Volume copies have been taken offline because the storage pool's cache is full of data that cannot be destaged. |
984007 | W | Volumes have been taken offline because a node's cache is full of data that cannot be destaged. |
984008 | W | Volume copies have been taken offline because a node's cache is full of data that cannot be destaged. |
984501 | I | The firmware level of an enclosure component is being updated. |
984502 | I | The firmware level updated has completed. |
984503 | I | The battery conditioning completed. |
984504 | I | The battery conditioning started. |
984505 | I | The statesave information for the enclosure was collected. |
984506 | I | The debug from an IERR was extracted to disk. |
984507 | I | An attempt was made to power on the slots. |
984508 | I | All the expanders on the strand were reset. |
984509 | I | The component firmware update paused to allow the battery charging to finish. |
984511 | I | The update for the component firmware paused because the system was put into maintenance mode. |
984512 | I | A component firmware update is needed but is prevented from running. |
985001 | I | The Metro Mirror or Global Mirror background copy is complete. |
985002 | I | The Metro Mirror or Global Mirror is ready to restart. |
985003 | W | Unable to find path to disk in the remote cluster (system) within the timeout period. |
986001 | W | The thin-provisioned volume copy data in a node is pinned. |
986002 | I | All thin-provisioned volume copy data in a node is unpinned. |
986010 | I | The thin-provisioned volume copy import has failed and the new volume is offline; either update the Lenovo Storage V7000software to the required version or delete the volume. |
986011 | I | The thin-provisioned volume copy import is successful. |
986020 | W | A thin-provisioned volume copy space warning has occurred. |
986030 | I | A thin-provisioned volume copy repair has started. |
986031 | I | A thin-provisioned volume copy repair is successful. |
986032 | I | A thin-provisioned volume copy validation is started. |
986033 | I | A thin-provisioned volume copy validation is successful. |
986034 | I | The import of the compressed-virtual volume copy was successful. |
986035 | W | A compressed-virtual volume copy space warning has occurred. |
986036 | I | A compressed-virtual volume copy repair has started. |
986037 | I | A compressed-virtual volume copy repair is successful. |
986038 | I | A compressed-virtual volume copy has too many bad blocks. |
986201 | I | A medium error has been repaired for the mirrored copy. |
986203 | W | A mirror copy repair, using the validate option cannot complete. |
986204 | I | A mirror disk repair is complete and no differences are found. |
986205 | I | A mirror disk repair is complete and the differences are resolved. |
986206 | W | A mirror disk repair is complete and the differences are marked as medium errors. |
986207 | I | The mirror disk repair has been started. |
986208 | W | A mirror copy repair, using the set medium error option, cannot complete. |
986209 | W | A mirror copy repair, using the resync option, cannot complete. |
987102 | W | Node coldstarted. |
987103 | W | A node power-off has been requested from the power switch. |
987104 | I | Additional Fibre Channel ports were connected. |
987301 | W | The connection to a configured remote cluster (system) has been lost. |
987400 | W | The node unexpectedly lost power but has now been restored to the cluster (system). |
988028 | I | Array validation started. |
988029 | I | Array validation complete. |
988100 | W | An overnight maintenance procedure has failed to complete. Resolve any hardware and configuration problems that you are experiencing on the cluster (system). If the problem persists, contact your Lenovo service representative for assistance. |
988300 | W | An array MDisk is offline because it has too many missing members. |
988301 | I | The rebuild for an array MDisk was started. |
988302 | I | The rebuild for an array MDisk has finished. |
988304 | I | A RAID array has started exchanging an array member. |
988305 | I | A RAID array has completed exchanging an array member. |
988306 | I | A RAID array needs resynchronization. |
988307 | I | A failed drive has been re-seated or replaced. The system has automatically configured the device. |
989001 | W | A storage pool space warning has occurred. |