Certain IBMEnterprise Storage
Server (ESS) types are supported for use with the Lenovo Storage V7000.
Before you delete or unmap a logical unit (LU) from the
Lenovo Storage V7000,
remove the LU from the storage pool. The following is supported:
- LU size of 1 GB to 1 PB.
- RAID 5 and RAID 10 LUs.
- LUs can be added dynamically.
Attention: When adding additional Lenovo Storage V7000 ports
to an existing LU, you must select the Use same ID/LUN
in source and target check box. Failure to select the Use
same ID/LUN in source and target checkbox can cause loss
in redundancy or a loss of data. If this checkbox is not available,
the option is not required. The detect MDisks task in the management GUI or
the detectmdisk command-line interface (CLI) command
must be run for the Lenovo Storage V7000 to
detect the new disks.