Global settings apply across an EMC CLARiiON system. Not all options are available on all EMC CLARiiON models.
Option | EMC CLARiiON default setting | Lenovo Storage V7000 required setting |
---|---|---|
Access Controls (Access Logix installed) | Not installed | Either Installed or Not Installed |
Subsystem Package Type | 3 | 3 |
Queue Full Status | Disable | Disable |
Recovered Errors | Disable | Disable |
Target Negotiate | Displays the state of the target negotiate bit. | Displays the state of the target negotiate bit. |
Mode Page 8 Info | Disable | Disable |
Base UUID | 0 | 0 |
Write Cache Enabled | Enabled | Enabled |
Mirrored Write Cache | Enabled | Enabled |
Write Cache Size | 600 MB | Default recommended |
Enable Watermarks | Enabled | Enabled |
Cache High Watermark | 96% | Default |
Cache Low Watermark | 80% | Default |
Cache Page Size | 4 Kb | 4 Kb |
RAID3 Write Buffer Enable | Enable | Default recommended |
RAID3 Write Buffer | 0 MB | Default recommended |