Configuring Compellent storage systems

The Lenovo Storage V7000 supports all models of Compellent systems (storage controllers).

For the latest supported models, see the following website:

http://support.lenovo.com/us/en/products/servers/lenovo-storage

Supported firmware levels for the Compellent system

The Compellent system must use a firmware level that is supported by the Lenovo Storage V7000. For specific firmware levels and the latest supported hardware, see the following website:

http://support.lenovo.com/us/en/products/servers/lenovo-storage

Concurrent maintenance on the Compellent system

Concurrent maintenance is the capability to perform I/O operations to a Compellent system while simultaneously performing maintenance operations on it. You can perform nondisruptive maintenance procedures concurrently on the following components:

User interfaces on the Compellent system

The Compellent Storage Center GUI (graphical user interface) is used to manage the storage center. Compellent provides access to your Compellent system from any standard Internet browser or from any host computer via a local area network (LAN) or a wide area network (WAN).

Logical unit creation, deletion, and migration for Compellent systems

Before you create, delete, or migrate logical units, you must read the storage configuration guidelines that are specified in the Compellent documentation.

Cabling the Compellent system

Figure 1 shows the suggested cabling for attachment of the Compellent storage system to Lenovo Storage V7000.
Figure 1. Suggested cabling to attach the Compellent storage system
Configure Fabric 1 to active port numbers 1 and 5 and reserve port numbers 2 and 6. Configure Fabric 2 to the remaining port numbers.

Using the Compellent GUI to create storage pools

On the Compellent storage system, a storage pool is a collection of physical disks. In most implementations, all the disks are allocated to the assigned pool, and the data is automatically arranged into a tier of storage.

To create a storage pool, follow either of these tasks:
  • In the lower-left pane, click Disks once. Left-click and select Manage Unassigned Disks.
  • In the upper right, click Storage Management. From the list, select Disk > Manage Unassigned Disks.
You can then select disks and create a new storage pool.

Using the Compellent GUI to create volumes

To create a volume, follow either of these tasks:
  • In the lower-left pane, click Storage once. Left-click and select Create Volume.
  • In the upper right, click Storage Management. From the list, select Volume > Create Volume.
You can then select a storage pool, specify a size, and create a new volume.

Using the Compellent GUI to create servers

To assign storage to the Lenovo Storage V series, you must create a server object that represents each storage node in a Lenovo Storage V seriesclustered system.

To create a server, follow either of these tasks:
  • In the lower-left pane, click Server once. Left-click and select Create Server.
  • In the upper right, click Storage Management. From the list, select Server > Create Server.
You can then select the host bus adapters, assign a name, specify an operating system, and create a new server.

When you create a server object for a Lenovo Storage V series storage node, select Other > Other MultiPath as the operating system. After you create all your storage nodes as servers, it is recommended that you create a server cluster and add all related nodes to it.

Using the Compellent GUI to map volumes to servers

To map a volume to a server or server cluster, follow either of these tasks:
  • In the Servers section in the lower-left pane, click once on the server or server cluster object. Left-click and select Map Volume to Server.
  • In the upper right, click Storage Management. From the list, select Volume > Map Volume to Server.
You then can select the volume and perform the volume mapping.

Migrating volumes

You can use the standard migration procedure to migrate volumes from the Compellent system to the Lenovo Storage V7000 system.

Sharing the Compellent between a host and the Lenovo Storage V7000

You can configure your environment so that other hosts can communicate with the Compellent system for storage requirements that fall outside of the Lenovo Storage V7000. You can also configure hosts that communicate with the Lenovo Storage V7000 directly for storage to also communicate directly with the Compellent Storage Center for storage. Ensure that you carefully plan and have suitable documentation before you follow either of these scenarios.

Quorum disks on the Compellent system

The Lenovo Storage V7000 can use logical units (LUs) that are exported by the Compellent system as quorum disks.

Advanced functions for the Compellent system