Use the chnodeled command
to turn the identification light-emitting diode (LED) on or off for
the specified node or control canister.
Syntax
sataskchnodeled { -on | -off } [ panel_name ]
Parameters
- -on | -off
- (Required) Turns the location LED for the specified
node or control canister on or off.
- panel_name
- (Optional) Specifies a unique panel name used to apply the command
to a valid node on the fabric.
Note: If panel_name is
not supplied, this applies to the node on which the command is running.
Description
This
command turns on or off the canister location LED.
Note: The location
LED is mapped onto the physical LEDs using different methods, depending
on your hardware. Refer to the documentation for your hardware platform
for more information.
An invocation example
to turn on the LED to identify the battery in slot 2 on
node KP2812
satask chnodeled -on -battery 2 KP2812
The
resulting output:
No feedback
An invocation example
to turn on the LED to identify the battery on node 2
satask chnodeled -on -battery 2
The
resulting output:
No feedback
An invocation example
to allow the node to identify the LED
satask chnodeled -on
The
resulting output:
No feedback
An invocation example to turn on the
LED for canister 1 in control enclosure 02
satask chnodeled -on 02-1
The
resulting output:
No feedback