Use the chenclosure command to modify
enclosure properties.
Syntax
chenclosure { -identify { yes | no } | -managed { yes | no } | -idenclosure_id } enclosure_id
Parameters
Note: Optional parameters
are mutually exclusive. Exactly one of the optional parameters must
be set.
- -identify yes | no
- (Optional) Causes the identify LED start or stop flashing.
- -managed yes|no
- (Optional) Changes the enclosure to a managed or
unmanaged enclosure.
- -id enclosure_id
- (Optional) Changes the enclosure ID after you replace the enclosure,
and enables you to control what is on the front panel.
- enclosure_id
- (Required) Specifies the enclosure you want to modify.
Description
Use
this command to modify enclosure properties.
An
invocation example to change the enclosure ID from 7 to 4
chenclosure -id 4 7
The
resulting output:
No feedback
An invocation
example to change enclosure 1 to unmanaged
chenclosure -managed no 1
The
resulting output:
No feedback
An invocation example to make the
identify LED on enclosure 1 stop flashing
chenclosure -identify no 1
The
resulting output: