chenclosure

Use the chenclosure command to modify enclosure properties.

Syntax

chenclosure { -identify { yes | no } | -managed { yes | no } | -idenclosure_id } enclosure_id

Parameters

Note: Optional parameters are mutually exclusive. Exactly one of the optional parameters must be set.
-identify yes | no
(Optional) Causes the identify LED start or stop flashing.
-managed yes|no
(Optional) Changes the enclosure to a managed or unmanaged enclosure.
-id enclosure_id
(Optional) Changes the enclosure ID after you replace the enclosure, and enables you to control what is on the front panel.
enclosure_id
(Required) Specifies the enclosure you want to modify.

Description

Use this command to modify enclosure properties.

An invocation example to change the enclosure ID from 7 to 4

chenclosure -id 4 7

The resulting output:

No feedback

An invocation example to change enclosure 1 to unmanaged

chenclosure -managed no 1

The resulting output:

No feedback

An invocation example to make the identify LED on enclosure 1 stop flashing

chenclosure -identify no 1

The resulting output:

No feedback