Configuring the AIX operating system

You must configure the AIX operating system before you can use IBM®System p hosts with the Lenovo Storage V7000 system.

Before you configure the AIX host operating systems, the following tasks must be completed:
After the prerequisite tasks are complete, use the following general steps to configure your AIX host system.
  1. Zone the host system to the Lenovo Storage V7000 on the Fibre Channel SAN.
  2. Install the appropriate multipathing driver for your host system to enable the management of multiple paths to Lenovo Storage V7000volumes.
    Note: The subsystem device driver (SDD) and the subsystem device driver path control module (SDDPCM) for the AIX operating system support System p AIX host systems in a clustered-system environment. To have failover protection on an open system, these multipath drivers require a minimum of two Fibre Channel adapters. The maximum number of Fibre Channel ports that are supported in a single host (or logical partition) is four. This can be four single-port adapters or two dual-port adapters or a combination, as long as the maximum number of ports that are attached to the Lenovo Storage V7000 system does not exceed four.
  3. Create the host system on the Lenovo Storage V7000 system, using the worldwide port names (WWPNs). Map the volume to the host as required.
  4. Create volumes/disks on your host using instructions in your host system publications.