Two SAS ports are located in the rear of the Lenovo Storage V7000 Gen2 expansion canister.
SAS ports are numbered at the bottom of the port, with 1 on the left and 2 on the right, as shown in Figure 1. Use of port 1 is required. Use of port 2 is optional. Each port connects four data channels.
Name | Color | State | Meaning |
---|---|---|---|
SAS Port 1 Link | Green | OFF | No link connection on any phys (lanes). The connection is down. |
ON | There is a connection on at least one phy. At least one of the phys to that connector is up. | ||
SAS Port 1 Fault | Amber | OFF | No fault. All four phys have a link connection. |
ON | This can indicate a number of different error
conditions:
|
||
SAS Port 2 Link | Green | OFF | No link connection on any phys (lanes). The connection is down. |
ON | There is a connection on at least one phy. At least one of the lanes to that connector is up. | ||
SAS Port 2 Fault | Amber | OFF | No fault. All four phys have a link connection. |
ON | This can indicate a number of different error
conditions:
|