702: A Fibre Channel adapter has a PCI error.

Explanation

A Fibre Channel adapter has a PCI error. The adapter is located on the node canister system board.

This node error does not, in itself, stop the node canister becoming active in the system. However, the Fibre Channel network might be being used to communicate between the node canisters in a clustered system. Therefore, it is possible that this node error indicates the reason why the critical node error 550 A cluster cannot be formed because of a lack of cluster resources is reported on the node canister.

Data:

  • A number indicating the adapter location. Location 0 indicates the adapter integrated into the system board is being reported.

User Response

  1. If possible, use the management GUI to run the recommended actions for the associated service error code.
  2. Use the procedures to restart (physically remove and reseat) a node canister.
  3. As the adapter is located on the system board, replace the node canister by using the remove and replace procedures.

Possible Cause-FRUs or other cause: