Explanation
The node has been unable to read the saved cluster
state and configuration data from its internal drive because of a
read or medium error.
User Response
In the sequence shown, exchange
the FRUs for new FRUs.
Possible CauseFRUs or other:
- 2145-CG8 or 2145-CF8
- Disk drive (50%)
- Disk controller (30%)
- Disk backplane (10%)
- Disk signal cable (8%)
- Disk power cable (1%)
- System board (1%)
User Response
Follow troubleshooting procedures
to fix the hardware:
- The drive of the node canister cannot be replaced individually.
Follow the hardware remove and replace instructions to change the
node canister.
Possible CauseFRUs or other:
User Response
Follow troubleshooting
procedures to fix the hardware:
- The drive of the node canister cannot be replaced individually.
Follow the hardware remove and replace instructions to change the
node canister.
Possible CauseFRUs or other: