Explanation
The node does not have sufficient connectivity
to other nodes or the quorum device to form a cluster.
Attempt
to repair the fabric or quorum device to establish connectivity. If
a disaster occurred and the nodes at the other site cannot be recovered,
then it is possible to allow the nodes at the surviving site to form
a system by using local storage.
User Response
Follow troubleshooting procedures to correct connectivity
issues between the cluster nodes and the quorum devices.
- Check for any node errors that indicate issues with
Fibre Channel connectivity. Resolve any issues.
- Ensure that the other nodes in the cluster are powered on and
operational.
- Using the SAT GUI or CLI (sainfo lsservicestatus), display the Fibre Channel port status. If any port is not
active, perform the Fibre Channel port
problem determination procedures.
- Ensure that Fibre Channel network
zoning changes have not restricted communication between nodes or
between the nodes and the quorum disk.
- Perform the problem determination procedures for
the network.
- The quorum disk failed or cannot be accessed. Perform the problem
determination procedures for the disk controller.
- As a last resort when the nodes at the other site cannot be recovered, then it is possible to
allow the nodes at the surviving site to form a system by using local site storage:
To avoid data
corruption ensure that all host servers that were previously accessing the system have had all
volumes unmounted or have been rebooted. Ensure that the nodes at the other site are not operational
and are unable to form a system in the future.
After starting this command, a full
resynchronization of all mirrored volumes is completed when the other site is recovered. This is
likely to take many hours or days to complete.
Contact IBM support personnel if you are
unsure.
Warning: Before continuing, confirm that you have taken the following actions
- failure to perform these actions can lead to data corruption that is undetected by the system but
affects host applications.
- All host servers that were previously accessing the system have had all volumes unmounted or
have been rebooted.
- Ensure that the nodes at the other site are not operating as a system and actions have been
taken to prevent them from forming a system in the future.
After these actions have been taken, the satask overridequorum can be
used to allow the nodes at the surviving site to form a system that uses local
storage.