3080: Global or Metro Mirror relationship or consistency group with deleted partnership

Explanation

A Global Mirror or Metro Mirror relationship or consistency group exists with a cluster whose partnership is deleted.

Beginning with SAN Volume Controller software version 4.3.1 this configuration is not supported and should be resolved. This condition can occur as a result of an update to SAN Volume Controller software version 4.3.1 or later.

User Response

The issue can be resolved either by deleting all of the Global Mirror or Metro Mirror relationships or consistency groups that exist with a cluster whose partnership is deleted, or by recreating all of the partnerships that they were using.

The error will automatically fix when the situation is resolved.

Possible Cause-FRUs or other: