Explanation
SAS cable fault type 2.
User Response
Complete the following steps:
Note: After each action,
check to see whether the canister ports at both ends of the cable
are excluded. If the ports are excluded, then enable them by issuing
the following command:
chenclosurecanister-excludesasport no-portX
- Reset this canister and the upstream canister.
The upstream
canister is identified in sense data as enclosureid2, faultobjectlocation2...
- Reseat cable between the two ports that are identified in the
sense data.
- Replace cable between the two ports that are identified in the
sense data.
- Replace this canister.
- Replace other canister (enclosureid2).
Possible Cause-FRUs or other: