Each Lenovo Storage V series system is a virtualizing RAID storage system. Lenovo Storage V3700 V2, Lenovo Storage V3700 V2 XP, Lenovo Storage V5030, and Lenovo Storage V5030Fsystems are Lenovo Storage V series systems.
Lenovo Storage V series system is built with Spectrum Virtualizesoftware, which is part of the Spectrum Storage family.
The Lenovo Storage V series storage system consists of a set of drive enclosures. The control enclosure contains disk drives and two node canisters. Expansion enclosures contain disk drives and two expansion canisters.
Lenovo Storage V series Model | Machine type / model | Part Number | Warranty | Description |
---|---|---|---|---|
Lenovo Storage V3700 V2 | 6535-HC1 | 6535C1D | 3 years | 12-slot control enclosure for 3.5-inch drives |
6535-HC4 | 6535C2D | 3 years | 24-slot control enclosure for 2.5-inch drives | |
Lenovo Storage V3700 V2 XP | 6535-HC2 | 6535C3D | 3 years | 12-slot control enclosure for 3.5-inch drives |
6535-HC5 | 6535C4D | 3 years | 24-slot control enclosure for 2.5-inch drives | |
Lenovo Storage V5030 | 6536-HC3 | 6536C12 | 3 years | 12-slot control enclosure for 3.5-inch drives |
6536-HC6 | 6536C22 | 3 years | 24-slot control enclosure for 2.5-inch drives | |
6536-HC3 | 6536C32 | 5 years* | 12-slot control enclosure for 3.5-inch drives | |
6536-HC6 | 6536C42 | 5 years* | 24-slot control enclosure for 2.5-inch drives | |
Lenovo Storage V5030F | 6536-HC6 | 6536B1F | 3 years | 24-slot control enclosure for 2.5-inch flash drives |
6536-HC6 | 6536B2F | 5 years* | 24-slot control enclosure for 2.5-inch flash drives |
Lenovo Storage V series Model Model | Machine type / model | Part Number | Warranty | Description |
---|---|---|---|---|
Lenovo Storage V3700 V2 and Lenovo Storage V3700 V2 XP | 6535-HC7 | 6535N1F | 3 years | 12-slot expansion enclosure for 3.5-inch drives |
6535-HC8 | 6535N2F | 3 years | 24-slot expansion enclosure for 2.5-inch drives | |
Lenovo Storage V5030 | 6536-HC7 | 6536N13 | 3 years | 12-slot expansion enclosure for 3.5-inch drives |
6536-HC8 | 6536N23 | 3 years | 24-slot expansion enclosure for 2.5-inch drives | |
6536-HC7 | 6536N33 | 5 years* | 12-slot expansion enclosure for 3.5-inch drives | |
6536-HC8 | 6536N43 | 5 years* | 24-slot expansion enclosure for 2.5-inch drives | |
Lenovo Storage V5030F | 6536-HC8 | 6536B3F | 3 years | 24-slot expansion enclosure for 2.5-inch flash drives |
6536-HC8 | 6536B4F | 5 years* | 24-slot expansion enclosure for 2.5-inch flash drives |
Figure 1 shows a Lenovo Storage V series system as a traditional RAID storage system. The internal drives are configured into arrays. Volumes are created from those arrays.
The two node canisters are known as an I/O group. The node canisters are responsible for serving I/O on the volumes. Because a volume is served by both node canisters, no availability is lost if one node canister fails or is taken offline. The Asymmetric Logical Unit Access (ALUA) features of SCSI are used to disable the I/O for a node before it is taken offline or when a volume cannot be accessed via that node.
The topology property of a system can be set to one of the following states:
The node canisters can be arranged in different topologies.
Standard topology, where all node canisters in the system are at the same site.
HyperSwap topology, where the system consists of at least two I/O groups. Each I/O group is at a different site. Both nodes of an I/O group are at the same site. A volume can be active on two I/O groups so that it can immediately be accessed by the other site when a site is not available. The HyperSwap topology is supported on Lenovo Storage V5030 systems.
The Lenovo Storage V series nodes operate as a single system and present a single point of control for system management and service. System management and error reporting are provided through an Ethernet interface to one of the nodes in the system, which is called the configuration node. The configuration node runs a web server and provides a command-line interface (CLI). The configuration node is a role that either node can take. If the current configuration node fails, the other node becomes the configuration node. Each node also provides a command-line interface and web interface for servicing hardware.
I/O operations between hosts and Lenovo Storage V series nodes and between Lenovo Storage V series nodes and RAID storage systems use the SCSI standard. The Lenovo Storage V series nodes communicate with each other by using private SCSI commands.
Fibre Channel and Fibre Channel over Ethernet (FCoE) connectivity is supported on Lenovo Storage V series with the optional FCoE feature installed.
Table 3 shows the fabric types that can be used for communicating between hosts, nodes, and RAID storage systems. All installed fabric types can be used at the same time.
Communications type | Host to Lenovo Storage V series | Lenovo Storage V series to storage system |
---|---|---|
iSCSI (1 Gbps Ethernet) | Yes | No |
iSCSI (10 Gbps Ethernet) | Yes Note: Lenovo Storage V3700 V2 and Lenovo
Storage V3700 V2 XP systems must have the optional 10 Gbps Ethernet host interface
adapter to use Ethernet for host attachment. Lenovo Storage V5030 and Lenovo Storage V5030F systems have a 10 Gbps Ethernet port that is preinstalled on
the system for host attachment.
|
No |
iSCSI (25 Gbps Ethernet) | Yes | No |
Fibre Channel over Ethernet | Yes, with 10 Gbps Ethernet host interface adapter | Yes, with 10 Gbps Ethernet host interface adapter |