After you install the QLogic HBA and the device driver on hosts that run a Microsoft Windows Server operating system, you must configure the HBA.
For more information about supported QLogic models, see the following website:
https://datacentersupport.lenovo.com/
Set the execution throttle to a suitable queue depth for your environment, for example, a value of 100. For more information about the execution throttle and queue depth, see QLogic documentation.
If you are using subsystem device driver (SDD) 1.6 or later, set Enable Target Reset to No. See Table 1 to include the required parameters for the registry key.
Key | Required parameters |
---|---|
HKEY_LOCAL_MACHINE > SYSTEM > CurrentControlSet > Services > ql2xxx > Parameters > Device > DriverParameters | Buschange=0;FixupInquiry=1 Note: If you are using QLogic driver version 9.1.2.11 or later, Buschange cannot be set to zero. See your device driver
documentation for details.
|