IBM DS5000, IBM
DS4000, and IBM DS3000 storage systems are
supported by the system.
The following steps provide the supported options and impact on the system.
- Set the host type for the system to IBM TS SAN VCE.
For higher security, create a storage partition for every host that has access to the storage system. If you set a default
host group and add another host other than the system to the default group, the new host
automatically has full read and write access to all LUNs on the storage system.
- See the following website for the scripts that are available to change the setup of the IBM DS5000, IBM
DS4000, or IBM DS3000 system:
The following limitations apply to partitions:
- Only one IBM DS5000, IBM
DS4000, or IBM DS3000 system storage
partition that contains any of the ports of any of the nodes in a system can be created.
- Map only one partition to any of the ports on any of the nodes that are in the system to
avoid unexpected behavior. For example, you can lose access to your storage or you might not
receive warning messages, even if events are logged in the system event log.
The following limitation applies to
IBM DS5000,
IBM
DS4000, or
IBM DS3000 Copy Services:
- Do not use IBM DS5000, IBM
DS4000, or IBM DS3000 Copy Services when
the system is attached to an IBM DS5000, IBM
DS4000, or IBM DS3000 system.
- You can use partitioning to allow IBM DS5000, IBM
DS4000, or IBM DS3000 Copy Services usage for
other hosts.
The following information applies to the access LUN (also known as the Universal
Transport Mechanism (UTM) LUN):
- The access/UTM LUN is a special LUN that allows an IBM DS5000, IBM
DS4000, or IBM DS3000 system to be configured
through software over the Fibre Channel connection.
- The access/UTM LUN does not have to be in the partition that contains the system ports
because the access/UTM LUN is not required by the system. If the access/UTM LUN is not in the
partition, no events are generated.
- If the access/UTM LUN is included in the Lenovo Storage V series partition, the access/UTM LUN
must not be configured as logical unit number 0. If the system partition (the host group) was
created with multiple hosts, the access LUN must be present in all hosts and must be the same
logical unit number.
The following information applies to the logical unit (LU):
- The system attempts to follow the preferred ownership that is specified by the storage
system. You can specify which
controller (A or B) is used for I/O operations to an LU.
- If the system can see the ports of the preferred controller and event conditions do not
exist, the system accesses the LU through one of the ports on the preferred controller.
- If event conditions exist, the system ignores the preferred ownership of the IBM DS5000, IBM
DS4000, or IBM DS3000 system.