The AIX audit subsystem allows system administrators to monitor and record security-related events on the system.
The errors that are shown in the following sample event log indicate that the HBA was unable to open an I/O request on the first attempt because the DMA resources were too low.
LABEL: FCS_ERR6 IDENTIFIER: D0EAC662 Date/Time: Wed Dec 4 16:41:48 MST Sequence Number: 1949119 Machine Id: 0021DF9A4C00 Node Id: lode1 Class: H Type: TEMP Resource Name: fcs0 Resource Class: adapter Resource Type: df1000f9 Location: 3V-08 VPD: Part Number.................03N2452 EC Level....................D Serial Number...............1809102EC Manufacturer................0018 FRU Number..................09P0102 Network Address.............10000000C92BB50F ROS Level and ID............02C03891 Device Specific.(Z0)........1002606D Device Specific.(Z1)........00000000 Device Specific.(Z2)........00000000 Device Specific.(Z3)........02000909 Device Specific.(Z4)........FF401050 Device Specific.(Z5)........02C03891 Device Specific.(Z6)........06433891 Device Specific.(Z7)........07433891 Device Specific.(Z8)........20000000C92BB50F Device Specific.(Z9)........CS3.82A1 Device Specific.(ZA)........C1D3.82A1 Device Specific.(ZB)........C2D3.82A1 Description MICROCODE PROGRAM ERROR Probable Causes ADAPTER MICROCODE Failure Causes ADAPTER MICROCODE Recommended Actions IF PROBLEM PERSISTS THEN DO THE FOLLOWING CONTACT APPROPRIATE SERVICE REPRESENTATIVE Detail Data SENSE DATA 0000 0000 0000 0029 0002 0039 0000 0000 0061 1613 0090 D5FD 0000 C98B 0000 012C 0000 0000 0000 0003 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0608 0000 0000 0010 0000 0000 0000 0000 0000 2710 0000 07D0 0000 076C 0000 0064 0000 000F 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000