Explanation
A Fibre Channel adapter that was previously present has not
been detected. The adapter might have been deliberately removed, it might not be correctly
installed, or it might have failed.
Data:
- Location—A number indicating the adapter location. The location indicates an adapter slot.
See the node description for the definition of the adapter slot locations.
User Response
- If possible, this noncritical node error should be serviced using the management GUI and running the recommended
actions for the service error code.
There are a number of possibilities.
- If you have deliberately removed the adapter (possibly replacing it with a different adapter
type), you will need to follow the management GUI recommended actions to mark the hardware change as intentional.
- Use the remove and
replace procedures to remove and open the canister and check the adapter is fully installed.
- If the previous steps have not isolated the problem, use the remove and
replace procedures to replace the adapter, if this does not fix the problem replace the
canister.
Possible Cause—FRUs or other cause:
- Fibre Channel adapter
- Node canister