558: The node is unable to communicate with other nodes.

Explanation

The system cannot see the Fibre Channel fabric or the Fibre Channel adapter port speed might be set to a different speed than that of the Fibre Channel fabric.

User Response

Ensure that:

  1. The Fibre Channel network fabric switch is powered-on.
  2. At least one Fibre Channel cable connects the system to the Fibre Channel network fabric.
  3. The Fibre Channel adapter port speed is equal to that of the Fibre Channel fabric.
  4. At least one Fibre Channel adapter is installed in the system.
  5. Go to the Fibre Channel MAP.

Possible Cause-FRUs or other: