Explanation
The amount of memory detected in the node canister differs from the amount required for the
canister to operate as an active member of a system. The error code data shows the detected memory,
in MB, followed by the minimum required memory, in MB, there is then a series of values indicating
the amount of memory, in GB, detected in each memory slot.
Data:- Detected memory in MB
- Minimum required memory in MB
- Memory in slot 1 in GB
- Memory in slot 2 in GB
- ...
- Memory in slot n in GB
Explanation
The amount of memory detected in the node canister differs from the amount required for the
canister to operate as an active member of a system. The error code data shows the detected memory,
in MB, followed by the minimum required memory, in MB; there is then a series of values indicating
the amount of memory, in GB, detected in each memory slot.
This might be reported because a memory module has failed or because a memory module has been
removed from the canister.
Note: It is not possible to remove an extra memory module installed as part of a cache update option from a canister that is part of an
operational system. The memory must be reinstalled to allow the canister to become active again. To
remove the cache update option, the
management GUI remove node action should be used on the canister before removing the memory.
Data:- Detected memory in MB
- Minimum required memory in MB
- Memory in slot 1 in GB
- Memory in slot 2 in GB
- ...
- Memory in slot n in GB
Explanation
The amount of memory detected in the node differs from the amount required for the node to
operate as an active member of a system. The error code data shows the detected memory, in MB,
followed by the minimum required memory, in MB. The next series of values indicates the amount of
memory, in GB, detected in each memory slot.
Data:- Detected memory in MB
- Minimum required memory in MB
- Memory in slot 1 in GB
- Memory in slot 2 in GB
- ...
- Memory in slot n in GB
Explanation
The amount of memory detected in the node canister differs from the amount required for the
canister to operate as an active member of a system. The error code data shows the detected memory
(in MB) followed by the minimum required memory (in MB). A series of values indicates the amount of
memory (in GB) detected in each memory slot.
Data:- Detected memory in MB
- Minimum required memory in MB
- Memory in slot 1 in GB
- Memory in slot 2 in GB
- ...
- Memory in slot n in GB
User Response
- Use the hardware remove and replace memory module procedure to
install a new memory module.
Possible Cause—FRUs or other:
User Response
- If the memory has not been deliberately removed, use the remove and replace memory module
procedure to install a new memory module. The node error data indicates which of the two memory
slot's memory is not working. Slot 1 is closest to the CPU, slot 2 is closest to the battery.
- If the memory has been deliberately removed, it must be replaced.
Possible Cause—FRUs or other:
User Response
Check the memory size of another 2145 that is in the same cluster.
Possible
Cause-FRUs or other:
User Response
Contact your hardware manufacturer.
User Response
Follow troubleshooting procedures to fix the hardware:
- Use the hardware remove and replace node canister procedure to install a new node canister.